Equipment Description
51
Enables/disables the mapping of the storage slots whenever the Scalar Library is powered-up, after the
sliding access panel has been opened and then closed, or if a SCSI bus Reset occurs.
❐
To disable the mapping of slots use the
UP
or
DOWN
keys to select "N". Press
ENTER
to execute
the change.
Note
INIT MAPPING default setting is Y.
Note
Disabling INIT MAPPING by selecting “N” will force INIT
SCAN BARCODES to “N” ( see below).
Init Scan Barcodes
Enables/disables the scanning of the cartridge barcodes whenever the Scalar Library is powered-up, or
after the sliding access panel has been opened and then closed. The application software overrides the
setting of this parameter. If Barcode Scanner configuration is set to No, Initialize Scan Barcodes is
ignored, and the barcode reader is not available to the application software.
❐
To disable the scanning of barcodes use the
UP
or
DOWN
keys to select "N". Press
ENTER
to
execute the change.
Note
INIT SCAN BARCODES default setting is Y.
Note
Enabling INIT SCAN BARCODES by selecting “Y” will force
INIT MAPPING to “Y” ( see above).