Configuring the Fibre Channel Subsystem
31
Trace Settings Configuration
Trace Settings Configuration allows you to set the trace level for diagnostics. For performance reasons, trace
settings should all be turned off, except in cases where a problem might be detected by a trace. The default
configuration has all levels set to
ON
. Pressing 7 on the Configuration Menu results in the following display:
Trace Settings
Build Level: a9802
Level 0 : ON Level 1 : OFF
Level 2 : OFF Level 3 : OFF
Level 4 : OFF Level 5 : OFF
Level 6 : OFF Level 7 : OFF
U) Update Current Operating Trace Levels
X) Return to previous menu
Enter trace level to change >
Note
The Trace capability is provided for diagnostic purposes only.
You should only change the Trace Level settings when
instructed to do so by ADIC Technical Support. Call ADIC
Technical Support at (425) 883-HELP (4357) for additional
information.
To change the trace level:
1.
Enter a trace level number corresponding to the trace level you wish to change. This toggles the current
value between
ON
and
OFF
.
2.
After all settings have been toggled to the value you desire, you can make them permanent by selecting
U
to update the current operating trace level. (Note that Step 4, below, is still necessary, however.
3.
Press
X
to return to the Configuration Menu.
4.
Press
A
to save the your configuration settings.
Save Configuration
Pressing
A
on the Configuration Menu saves all currently changed values. See the previous examples for the
use of this option.
Restore Last Saved Configuration
Pressing
B
on the Configuration Menu restores all values from the previously saved configuration.
Reset Configuration to Factory Defaults
Pressing
C
on the Configuration Menu restores the factory default configuration. The following table
summarizes the default settings:
Setting
Value
Baud Rate
9600
World Wide Name High
Unique value (set at factory)
Summary of Contents for Scalar 218FC
Page 1: ...Installation and Operating Guide Scalar 218FC Library...
Page 6: ...vi Blank Page...
Page 101: ...Diagnostics Menu 91 Blank Page...
Page 105: ...Error Codes 95 Blank Page...
Page 123: ...113 Index...