Electromagnetic Interference (EMI) Susceptibility
Quantum|ATL PowerStor L200 Series Library User’s Guide
69
Conducted
Emissions
1
This subsection includes conducted emission limits.
Table 21 Conducted
Emission Limits
Radiated
Emissions
1
This section lists the limits of radiated interference field strength,
in the frequency range from 30 MHz to 1000 MHz at a test distance
of 10 meters, for Class B equipment.
Table 22 Radiated
Emissions (30 MHz to
1000 MHz)
Radiated
Susceptibility
1
The radiated susceptibility limits for high frequency electric fields
(26 MHz to 1000 MHz) are:
•
3 V/m (rms) 80% modulated 1 kHz
•
No errors, no screen distortion (S/W recoverable errors)
•
No hardware failure
Frequency Range
(0.15 to 30 MHz)
Limits dB
Quasipeak
Average
0.15 to 0.050
66 to 56
†
56 to 46
0.50 to 5
56
46
5 to 30
60
50
†
The limit decreases with the logarithm of the frequency
Frequency Range = 30 MHz to
1000 MHz
Quasi-Peak Limit dB (uV/m)
@ 10 meters
30 MHz to 230 MHz
30
230 MHz to 1000 MHz
37
Above 1000 MHz
Not applicable
Summary of Contents for PowerStor L200
Page 1: ...Quantum ATL PowerStor L200 Series Library User s Guide 6322500 04 Ver 4 Rel 0...
Page 7: ...Contents Quantum ATL PowerStor L200 Series Library User s Guide vii Glossary 87 Index 93...
Page 8: ...Contents viii Quantum ATL PowerStor L200 Series Library User s Guide...
Page 10: ...Figures x Quantum ATL PowerStor L200 Series Library User s Guide...
Page 108: ...Glossary 92 Quantum ATL PowerStor L200 Series Library User s Guide...
Page 112: ...Index 96 Quantum ATL PowerStor L200 Series Library User s Guide...