Chapter 3 Operator Control Panel
Mode
34
Quantum|ATL PowerStor L200 Series Library User’s Guide
•
Sequential NOT Selected
•
Sequential Circ NOT Selected
•
Autoload Cart: N
•
Enable Barcode: N
•
AutoClean: N
4
Press Enter to toggle the mode options.
Enter
executes the Selected mode and toggles all other modes
to NOT Selected.
For example, if you toggle the Sequential mode to Selected, the
Random
and Sequential Circ modes are automatically toggled
to NOT Selected
.
Enter also toggles each of the Y and N
options.
5
Press Select to return to the main menu.
Optional
Autoclean Mode
3
If the optional autoclean is enabled, the time that a SCSI
Move
Media
command takes to complete increases from approximately
20 seconds to 60 seconds because the library must wait until
calibration is complete. If cleaning is required, the typical time
increases to a maximum of 10 minutes while the drive is cleaned.
To use:
1
Load the cleaning cartridge into slot 7.
2
Press Enter to enable AutoClean: Y.
When AutoClean is enabled, the status of slot 7 becomes
unviewable. The OCP cannot be used to load a cleaning cartridge.
After the manual cleaning cycle is complete, the second line of the
OCP will display an idle message. Turn off the library. Wait at
least ten seconds. Turn on the library. After the initialization
process is complete, set the AutoClean parameter to
N
. The
cleaning cartridge may then be ejected.
Summary of Contents for PowerStor L200
Page 1: ...Quantum ATL PowerStor L200 Series Library User s Guide 6322500 04 Ver 4 Rel 0...
Page 7: ...Contents Quantum ATL PowerStor L200 Series Library User s Guide vii Glossary 87 Index 93...
Page 8: ...Contents viii Quantum ATL PowerStor L200 Series Library User s Guide...
Page 10: ...Figures x Quantum ATL PowerStor L200 Series Library User s Guide...
Page 108: ...Glossary 92 Quantum ATL PowerStor L200 Series Library User s Guide...
Page 112: ...Index 96 Quantum ATL PowerStor L200 Series Library User s Guide...