The Error Screen
When the FastStor 1 detects an error condition, the red/amber Fault LED is
illuminated and one of the error screens appears on the front panel. Figure 7.1
illustrates how the FastStor 1 reports error conditions on the front panel display:
Error : 1109–6A0133
Failed to stow
at slot 9 (Drive)
Details Actions
Figure 7.1 Error Code Page
The top line shows an Error code in the following format: XXXX-YYRRVV
The XXXX is the error number, while the YY is the internal loader error code.
The RRVV is the FW revision numbers, where RR is the major revision and VV
is the minor revision.
The next two lines give more detailed error information. There are two option
buttons, “Details” and “Actions”. Pressing the Details button gives access to a
multi-page error description text. Pressing Action gives access to a set of
actions that can be taken to recover from the error. An example of pressing
“Details” and continuing with pressing “More” is shown in figures 7.2 and 7.3.
Reboot the Loader
and retry the
operation.
More Back
Figure 7.2 Example of detailed information
If the problem
persists please call
technical support.
Back
Figure 7.3 Example of further detailed information
In this example, pressing “Back” twice takes you back to the Error Code Page
(figure 7.1) where you can press “Actions” to go to the Actions menu. Figure 7.4
FastStor 1 Installation and User Guide
61