I
NSTALLING
H
ARDWARE
C
ONFIGURATION
G
ROUP
4-
3
4
Procedure:
1. In the
LAN Destination Tab
, choose the slot to be config-
ured. This should be the same slot that you have selected
in the Alert Policy Entry- Destination Selector field. That is
if you have chosen the Destination Selector as 4 in the
Alert Policy Entry page of Alert Policy Tab, then you have
to configure the 4th slot of LAN Destination Page.
2. Select the slot and click
Add
. This opens the
Add LAN
Destination entry
.
Figure 4-27. Add LAN Destination entry Page
3. In the
LAN Destination
field, the destination for the
newly configured entry is displayed and this is a read only
field.
4. In the
Destination Type
field, select the one of the types.
5. In the
Destination Address
field, enter the destination
address.
Table 4-34: PEF Management - LAN Destination
I
TEM
D
ESCRIPTION
LAN Destination
Displays Destination number for the newly
configured entry (read-only).
Destination Type
Destination type can be either an SNMP Trap or
an Email alert.
For Email alerts, the 3 fields - destination Email
address, subject and body of the message
needs to be filled. The SMTP server information
also has to be added - under
Configuration
> SMTP
.
For SNMP Trap, only the destination IP address
has to be filled.
Destination Address
If Destination type is SNMP Trap, then enter the
IP address of the system that will receive the
alert. Destination address will support the
following:
IPv4 address format.
IPv6 address format.
If Destination type is Email Alert, then give the
email address that will receive the email.
Subject & Message
These fields must be configured if email alert is
chosen as destination type. An email will be sent
to the configured email address in case of any
severity events with a subject specified in
subject field and will contain the message field's
content as the email body.
Add
To save the new LAN destination and return to
LAN destination list.
Cancel
To cancel the modification and return to LAN
destination list.
Note:
If Destination type is Email Alert, then give the email address that
will receive the email.
Summary of Contents for STRATOS S210 Series S210-X12MS
Page 21: ...About the Server Chapter 1 About the Server Chapter 1 ...
Page 37: ...Installing Hardware Chapter 2 Installing Hardware Chapter 2 ...
Page 78: ...BIOS Chapter 3 BIOS ...
Page 135: ...BMC Chapter 4 BMC Chapter 4 ...
Page 194: ...Jumpers and Connectors Chapter 5 Jumpers and Connectors Chapter 5 ...
Page 197: ...Rail Kit Assembly Chapter 6 Rail Kit Assembly Chapter 6 ...
Page 201: ...Troubleshooting Chapter 7 Troubleshooting Chapter 7 ...
Page 210: ...Safety Information Chapter 9 Safety Information Chapter 9 ...