7 – Setting Up Connections
Configuring Fibre Channel Devices
7-30
FS0054603-00 C
Q
7.4.1
Configuring Device Paths for this Host
You can configure device paths for a host as visible, hidden, or unconfigured. Use
the following options as appropriate:
■
Configuring, unconfiguring, and inversing the configuration of all device paths
(see section 7.4.1.1)
■
Configuring individual device paths
(see section 7.4.1.2)
NOTE:
There must be one visible path for the operating system to see a device.
7.4.1.1
Configuring, Unconfiguring, and Inversing the Configuration of All
Device Paths
Perform the following steps to configure, unconfigure, or inverse the configuration
of all device paths.
1. From the
Fibre Channel Port Configuration
dialog box
Device
menu, click
Configure
to configure the device paths on this host.
2. Select one of the following:
❑
Select
Configure All
to configure all unconfigured device paths.
❑
Select
unConfigure All
to unconfigure all configured device paths.
❑
Select
Inverse State
to set configured device paths as unconfigured and
unconfigured device paths as configured.
Summary of Contents for SANsurfer FC HBA Manager Application
Page 22: ...2 System Overview Troubleshooting 2 8 FS0054603 00 C Q Notes...
Page 28: ...4 System Requirements Supported QLogic HBAs 4 4 FS0054603 00 C Q Notes...
Page 68: ...6 Getting Started Refreshing the Configuration 6 20 FS0054603 00 C Q Notes...
Page 190: ...11 Updating the HBA Updating the HBA Driver 11 26 FS0054603 00 C Q Notes...
Page 208: ...A Frequently Asked Questions A 2 FS0054603 00 C Q Notes...
Page 218: ...D Contacting QLogic D 2 FS0054603 00 C Q Notes...