7 – Setting Up Connections
Configuring LUNs for a Device
7-32
FS0054603-00 C
Q
7.4.2.1
Enabling and Disabling All LUNs on this Host
You can configure LUN masking—setting LUNs masked or unmasked from the
operating system. Enabling a LUN sets the LUN as unmasked; disabling a LUN
sets the LUN as masked.
Perform the following steps to enable or disable all LUNs on this host:
1. From the
Fibre Channel Port Configuration
dialog box
LUNs
menu, select
Enable LUNs
.
2. Do one of the following:
❑
Select
Enable All
to configure all LUNs as enabled.
❑
Select
Disable All
to configure all LUNs as disabled.
❑
Select
Inverse State
to enable currently disabled LUNs and disable currently
enabled LUNs.
7.5
Configuring LUNs for a Device
Perform the following steps to configure individual LUNs for a selected device:
1. Do one of the following:
❑
In the
Fibre Channel Port Configuration
dialog box, click in the cell in the
device Node Name, device Port Name, or device Port ID column. From the
Device
menu, select
Configure LUNs
.
❑
In the
Fibre Channel Port Configuration
dialog box, right-click in the cell
in the device Node Name, device Port Name, or device Port ID column. From
the pop-up menu, select
Configure LUNs
.
❑
In the
Fibre Channel Port Configuration
dialog box, double-click in the
cell in the device Node Name, device Port Name, or device Port ID column.
From the pop-up menu, select
Configure LUNs
.
The following messages can display:
❑
If SANsurfer FC HBA Manager detects an invalid LUN configuration, the
detected invalid LUN configuration message displays. Invalid LUN
configurations include a LUN with contradictory enabled paths. All paths
must be enabled or disabled.
Click
OK
; auto configure runs automatically.
❑
If SANsurfer FC HBA Manager detects an invalid SAN fabric configuration,
the detected invalid SAN fabric message displays. Change this configuration
before continuing; it is beyond the scope of SANsurfer FC HBA Manager to
configure the SAN fabric. Click
OK
to continue.
Summary of Contents for SANsurfer FC HBA Manager Application
Page 22: ...2 System Overview Troubleshooting 2 8 FS0054603 00 C Q Notes...
Page 28: ...4 System Requirements Supported QLogic HBAs 4 4 FS0054603 00 C Q Notes...
Page 68: ...6 Getting Started Refreshing the Configuration 6 20 FS0054603 00 C Q Notes...
Page 190: ...11 Updating the HBA Updating the HBA Driver 11 26 FS0054603 00 C Q Notes...
Page 208: ...A Frequently Asked Questions A 2 FS0054603 00 C Q Notes...
Page 218: ...D Contacting QLogic D 2 FS0054603 00 C Q Notes...