Removing the Hard Drive
The hard drive is a hot-removable and hot-insertable field-replaceable unit (FRU) on the MAG-SM360 only.
The MAG-SM160 uses only one hard drive. When replacing the hard drive, insert the drive in the upper slot
where the service module is located. The hard drive and service module are mated through the chassis
midplane.
The MAG-SM360 uses two drives in RAID 1 formation. The order of the drives must be preserved if you remove
and replace the hard drives. For example, the upper drive and the lower drive should not be switched if you
replace a drive.
The MAG-SM361 drives are slot-dependent and are labeled either “top slot drive” and “bottom slot drive.”
Ensure that you insert drives in their correct slot location.
To remove a hard drive from the Pulse Secure Gateway chassis:
1.
Unlock the handle on the front of the hard drive assembly by pushing the handle release button. This
action causes the handle to unlock and spring open.
2.
To remove the hard drive, pull the drive out of the chassis using the handle. Do not remove the hard
drive from the hard drive assembly.
3.
Place the hard drive in the antistatic bag or on the antistatic mat on a flat, stable surface.
Removing an Integrated Access Service Module
Before you begin removing a service module from the Pulse Secure Gateway, make sure that you have taken
the necessary precautions to prevent ESD damage.
NOTE: If you do not intend to replace the service module, install a faceplate over the open slot. Faceplates
are required to ensure proper cooling and airflow in the Pulse Secure Gateway.
The MAG-SM160, MAG-SM360, MAG-SM161 and MAG-SM361 service modules are paired with fan trays and
hard drives. When moving a service module to a different slot, you must move the associated fan trays and
hard drives to the new location as well.
Before removing the service module, you must power down the service module.
•
If a MAG-CM060 CMC is installed in the chassis, use the set chassis fpc number power offcommand. For
more information, see set chassis fpc power on off.
•
If a MAG-CM060 CMC is not installed in the chassis, you must turn off the entire Pulse Secure Gateway.
To do this, press and hold the power button on the chassis back panel for 3 to 5 seconds.
Summary of Contents for MAG2600
Page 8: ...2016 Pulse Secure LLC All rights reserved 8 MAG Series Pulse Secure Gateways Hardware Guide...
Page 12: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 12...
Page 18: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 18...
Page 24: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 24...
Page 56: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 56...
Page 66: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 66...
Page 78: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 78...
Page 84: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 84...