MAG Series Pulse Secure Gateways Hardware Guide
Service modules are paired with fan trays and hard drives. Hard drives have a serial number sticker that
matches the associated service module. Placing the service module serial number sticker on the back
panel of the Pulse Secure Gateway ensures that you have the correct hard drive paired with the service
module.
3.
Install the MAG-SM161 in the open slot.
4.
Remove the blank fan tray covers on the back panel of the Pulse Secure Gateway directly behind the
MAG-SM161 and install the fan trays in the slots.
5.
NOTE: It is important that you install the fan trays directly behind the MAG-SM161 to ensure proper
airflow across the service module.
6.
Remove the blank hard drive cover on the back panel of the Pulse Secure Gateway directly behind the
MAG-SM161 and install the hard drive.
NOTE: Hard drives must be installed directly behind their corresponding service module. They are
labeled with the same serial number as their paired service module to ensure they are installed in the
correct slot. Do not interchange them.
If you do not install the hard drive in the correct slot, it will not be recognized by the MAG-SM161 and
you will receive a drive error when powering up the Pulse Secure Gateway.
If the hard drive or MAG-SM161 service module fails, the entire kit must be replaced. Since the hard
drive is paired to the specific hardware ID, a failure of the hard drive or the service module requires a
full replacement rather than individual component troubleshooting.
NOTE: If you later move the MAG-SM161 service module to a different slot, you must move its fan tray
and hard drive to the new location as well.
Installing the MAG-SM361 Kit
The MAG-SM361 kit includes:
•
One MAG-SM361 service module • Two fan trays
•
Two hard drives
The cover plate on the left can be removed to accommodate the MAG-CM361 Chassis Management Card.
The basic steps for installing the MAG-SM361 kit are:
1.
Remove the face plate on the Pulse Secure Gateway corresponding to the slot where you want to install
the MAG-SM361.
2.
Service modules include an additional serial number. Remove this serial number and place it on the
back panel of the Pulse Secure Gateway, directly behind the slot where you are installing the MAG-
SM361.
Service modules are paired with fan trays and hard drives. Hard drives have a serial number sticker that
matches the associated service module. Placing the service module serial number sticker on the back
panel of the Pulse Secure Gateway ensures that you have the correct hard drive paired with the service
module.
Summary of Contents for MAG2600
Page 8: ...2016 Pulse Secure LLC All rights reserved 8 MAG Series Pulse Secure Gateways Hardware Guide...
Page 12: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 12...
Page 18: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 18...
Page 24: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 24...
Page 56: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 56...
Page 66: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 66...
Page 78: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 78...
Page 84: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 84...