MAG Series Pulse Secure Gateways Hardware Guide
2.
Service modules include an additional serial number. Remove this serial number and place it on the
back panel of the Pulse Secure Gateway, directly behind the slot where you are installing the MAG-
SM160.
Service modules are paired with fan trays and hard drives. Hard drives have a serial number sticker that
matches the associated service module. Placing the service module serial number sticker on the back
panel of the Pulse Secure Gateway ensures that you have the correct hard drive paired with the service
module.
3.
Install the MAG-SM160 in the open slot.
4.
Remove the blank fan tray covers on the back panel of the Pulse Secure Gateway directly behind the
MAG-SM160 and install the fan trays in the slots.
NOTE: It is important that you install the fan trays directly behind the MAG-SM160 to ensure proper
airflow across the service module.
5.
Remove the blank hard drive cover on the back panel of the Pulse Secure Gateway directly behind the
MAG-SM160 and install the hard drive.
NOTE: Hard drives must be installed directly behind their corresponding service module. They are
labeled with the same serial number as their paired service module to ensure they are installed in the
correct slot. Do not interchange them.
If you do not install the hard drive in the correct slot, it will not be recognized by the MAG-SM160 and
you will receive a drive error when powering up the Pulse Secure Gateway.
If the hard drive or MAG-SM160 service module fails, the entire kit must be replaced. Since the hard
drive is paired to the specific hardware ID, a failure of the hard drive or the service module requires a
full replacement rather than individual component troubleshooting.
NOTE: If you later move the MAG-SM160 service module to a different slot, you must move its fan tray
and hard drive to the new location as well.
Installing the MAG-SM360 Kit
The MAG-SM360 kit includes:
•
One MAG-SM360 service module
•
Two fan trays
•
Two hard drives (RAID 1 configuration)
The cover plate on the left can be removed to accommodate the MAG-CM060 Chassis Management Card.
To perform the initial installation of the MAG-SM360 kit:
1.
Remove the faceplate on the Pulse Secure Gateway corresponding to the service module slot where you
want to install the MAG-SM360.
2.
Remove the service module serial number sticker and install the MAG-SM360 in the open slot.
Summary of Contents for MAG2600
Page 8: ...2016 Pulse Secure LLC All rights reserved 8 MAG Series Pulse Secure Gateways Hardware Guide...
Page 12: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 12...
Page 18: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 18...
Page 24: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 24...
Page 56: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 56...
Page 66: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 66...
Page 78: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 78...
Page 84: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 84...