![Pulse Secure MAG2600 Hardware Manual Download Page 61](http://html1.mh-extra.com/html/pulse-secure/mag2600/mag2600_hardware-manual_1625600061.webp)
MAG Series Pulse Secure Gateways Hardware Guide
© 2016 Pulse Secure, LLC., All rights reserved.
61
Powering On an AC-Powered Pulse Secure Gateway
To power on an AC-powered Pulse Secure Gateway:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one
of the ESD points on the chassis.
2.
Verify that the power supplies are fully inserted in the chassis.
3.
Verify that each AC power cord is securely inserted into the appliance inlet.
4.
Verify that an external management device is connected to the Pulse Secure Gateway CONSOLE port.
5.
Turn on the power to the external management device.
6.
Switch on the dedicated customer site circuit breakers for the power supplies. Follow the ESD and
safety instructions for your site.
7.
Turn on the AC power supply, and observe the status LEDs (where applicable) on each power supply
faceplate. If an AC power supply is correctly installed and functioning normally, the AC OK and DC OK
LEDs light steadily, and the PS FAIL LED is not lit.
To turn on the Pulse Secure Gateway:
•
On the MAG2600, press the power button on the front panel.
•
On the MAG4610, MAG6610, or MAG6611, press and hold the power button on the chassis back
panel for 3 to 5 seconds.
8.
If any of the status LEDs indicates that the Pulse Secure Gateway is not functioning normally, repeat the
installation and cabling procedures.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on. After
powering on a power supply, wait at least 60 seconds before turning it off.
If the system is completely powered off when you power on the power supply, the Pulse Secure
Gateway boots as the power supply completes its startup sequence.
After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the
status LEDs on the power supply and the show chassis command display—to indicate that the power
supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
9.
On the external management device connected to the Pulse Secure Gateway, monitor the startup
process to verify that the system has booted properly.
Summary of Contents for MAG2600
Page 8: ...2016 Pulse Secure LLC All rights reserved 8 MAG Series Pulse Secure Gateways Hardware Guide...
Page 12: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 12...
Page 18: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 18...
Page 24: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 24...
Page 56: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 56...
Page 66: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 66...
Page 78: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 78...
Page 84: ...MAG Series Pulse Secure Gateways Hardware Guide 2016 Pulse Secure LLC All rights reserved 84...