D-32
Psion Teklogix Omnii XT10 Hand-Held Computer User Manual
Appendix D: Teklogix Imagers Applet
Bar Code Symbologies – Descriptions
MSI Plessey
Minimum and Maximum Length
The length of a code refers to the number of characters (i.e., human readable characters), in-
cluding check digit(s). Double-tapping on these parameters displays a screen in which you
can set the minimum and maximum allowable code lengths –
2 to 60.
D.5.12 MSI Plessey
Enabled
Set this parameter to
on
to enable MSI.
Enable Plessey
Set this parameter to on to enable Plessey.
Check Char
When this parameter is set to
on
, the integrity of a “MSI Plessey” symbol is checked to
ensure that it complies with specified algorithms.
Minimum and Maximum Length
The length of a code refers to the number of characters (i.e., human readable characters), in-
cluding check digit(s). Double-tapping on these parameters displays a screen in which you
can set the minimum and maximum allowable code lengths –
4 to 48.
Plessey Minimum and Plessey Maximum Length
These parameters apply to Plessey bar codes.The length of a code refers to the number of
characters (i.e., human readable characters), including check digit(s). Double-tapping on
these parameters displays a screen in which you can set the minimum and maximum allow-
able code lengths –
4 to 48.
D.5.13 Code 11
Enabled
Set this parameter to
on
to enable “Code 11”.
Check Digits
Double-tapping on this parameter displays a dialog box in which you can choose
One Check
Digit
or
Two check digits
.
If this parameter is set to
One Check Digit
, it is assumed that the last digit is a check digit. If
it is set to
Two Check Digits
, it is assumed that the last two digits are check digits.