![Proware SB-3164E-G1S3 User Manual Download Page 52](http://html1.mh-extra.com/html/proware/sb-3164e-g1s3/sb-3164e-g1s3_user-manual_1620848052.webp)
iSCSI GbE to SAS/SATA II RAID Subsystem
52
User Manual
RG column description:
No.
Number of RAID group. The button next to the No. shows
the functions which can be executed.
Name
RAID group name.
Total(GB)
Total capacity of this RAID group.
Free(GB)
Free capacity of this RAID group.
#PD
The number of physical disks in RAID group.
#VD
The number of virtual disks in RAID group.
Status
The status of RAID group.
“Online”
Æ
the RAID group is online.
“Offline”
Æ
the RAID group is offline.
“Rebuild”
Æ
the RAID group is being rebuilt.
“Migrate”
Æ
the RAID group is being migrated.
“Scrub”
Æ
the RAID group is being scrubbed.
Health
The health of RAID group.
“Good”
Æ
the RAID group is good.
“Failed”
Æ
the hard drive is failed.
“Degraded”
Æ
the RAID group is not completed. The
reason could be lack of one disk or disk failure.
RAID
The RAID level of the RAID group.
Enclosure
RG locates on local or JBOD enclosure.
RG operations description:
Create
Create a RAID group.
Migrate
Migrate a RAID group. Please refer to next chapter for more
detail.
Activate
Activate a RAID group; it can be executed when RG status
is offline. This is for online roaming purpose.
Deactivate
Deactivate a RAID group; it can be executed when RG
status is online. This is for online roaming purpose.
Scrub
Scrub a RAID group. It does parity regeneration. It is
supported in RAID 3 / 5 / 6 / 30 / 50 / 60 only.