SECTION 5
Pronar RC2100-2
5.23
Hold the filter cover (2) with the other hand. After removing slide lock,
the cover is pushed off by the spring located in the filter housing.
The filter element and the filter body should be carefully cleaned and blown
through with compressed air. Assembly should be done in reverse order.
Cleaning the air filter (filters):
•
every 3 months of use,
5.4.4 DRAINING WATER FROM AIR TANK
Scope of maintenance activities
Tilt drain valve stem (1) located in the lower part of tank (1) – figure (5.9).
The compressed air in the tank causes the removal of water to the
exterior.
After releasing the valve stem, the valve should automatically close and stop
airflow from the tank.
If the valve stem resists returning to its position, then the whole drain
valve must be unscrewed and cleaned or replaced (if it is damaged) -
see section 5.3.5.
Summary of Contents for RC2100-2
Page 2: ......
Page 6: ......
Page 10: ...5 11 TROUBLESHOOTING 5 31 ...
Page 11: ...SECTION 1 BASIC INFORMATION ...
Page 24: ...PRONAR RC2100 2 SECTION 1 1 14 ...
Page 25: ...SECTION 2 SAFETY ADVICE ...
Page 40: ...Pronar RC2100 2 SECTION 2 2 16 FIGURE 2 3 Locations of information and warning decals ...
Page 41: ...SECTION 3 DESIGN AND OPERATION ...
Page 59: ...SECTION 4 CORRECT USE ...
Page 78: ...Pronar RC2100 2 SECTION 4 4 20 ...
Page 79: ...SECTION 5 MAINTENANCE ...
Page 110: ...Pronar RC2100 2 SECTION 5 5 32 FIGURE 5 12 Lubrication points part 1 ...
Page 111: ...SECTION 5 Pronar RC2100 2 5 33 FIGURE 5 13 Lubrication points part 2 ...
Page 119: ...NOTES ...
Page 120: ... ...
Page 121: ...ANNEX A Tyre dimensions LP TYRES WHEEL RIM 1 215 75 R17 5 135 133 J 17 5x6 75 ...