191
Product Manual
Managing with the CLI
Examples
event
event -v
event -l nvram
event -a clear -lnvram
event -c 200
event -a list -i852 -c200
Options
-a <action>
Specifies the action to perform.
list
(Default) Displays information and status of the enclosure.
mod Modifies settings. Requires the -s option.
locate Locates an enclosure by flashing its LEDs.
-e <encl id>
Enclosure ID. The default value is 1 if unspecified.
For list action, the default is for all enclosures if unspecified.
-s “<option>=<value>” Specifies the settings to change. Applies to the JBOD enclosures only.
tempwarning= (25-45) Enclosure warning theshold temperature, in degrees Celsius.
tempcritical=
(30-51) Enclosure critical theshold temperature, in degrees Celsius.
ctrltempwarning= (90-95) Controller warning theshold temperature, in degrees Celsius.
ctrltempcritical= (100-105) Controller critical threshold temperature, in degrees Celsius.
-t <FRU type> Specifies which type of FRU to locate. Requires -a locate option.
ctrl
Locates the controller.
cooling Locates the cooling unit.