119
TX500 series technical manual
8.5.5 Meter Characteristic
<METER CHAR>
- is used to select the meter type (operation) for the audio meters.
Pressing the button toggles between the two available options, PPM and VU.
If VU is selected on the
<METER CHAR>
button, the meter scale is fixed for analogue VU
and no further configuration options are available.
8.5.6 Meter Scale
The audio meter scale, once set as PPM, can be set to operate in one of three possible
modes.
<DIGITAL (DBFS)>
,
<PPM>
or
<NORDIC>
.
Pressing the
<METER SCALE>
button cycles around these options,
8.5.7 Line Up
<LINE UP>
- Pressing the <LINE UP> button sets the scale for the audio meters, when
configured for Digital DBFS operation, to indicate 0dBu at either -18.06dbFS or -20dbFS.
8.5.8 Peak Bar
<PEAK BAR>
- this allows the peak hold bar for all the meters to be selected, either turned
off or held for between one and ten seconds. The button will toggle through the available
options.