25 way ‘D’ type fixed sockets
Pin
SPARE 1
SPARE 2
AUTOMATION
1
SW1
SW1
AUTO ON
2
SW3
SW3
HOLD
3
SW5
SW5
SKIP NEXT
4
SW7
SW7
PREVIEW
5
N/C
N/C
RECUE
6
LED1
LED1
TAKE
7
LED3
LED3
DELETE
8
LED5
LED5
UNDELETE
9
N/C
N/C
ARROW UP
10
LED7
LED7
ARROW DOWN
11
N/C
N/C
STANDBY
12
N/C
N/C
EXPLODE BREAK
13
N/C
N/C
AUTO LED
14
SW2
SW2
HOLD LED
15
SW4
SW4
N/C
16
SW6
SW6
PREVIEW LED
17
SW8
SW8
N/C
18
SW COMMON
SW COMMON
N/C
19
LED 2
LED 2
TAKE LED
20
LED4
LED4
N/C
21
LED6
LED6
EXPLODE LED
22
LED8
LED8
12V OUT
23
LED COMMON
LED COMMON
LED COMMON
24
N/C
N/C
SW COMM
25
OV
OV
OV OUT
The connectors Spare 1 and 2, provide access to the two rows of eight pushbuttons below
the Bypass switch control button row. These buttons can be used to control any equipment
requiring a closing contact. However in systems with multi level audio, or if the panel is to
provide control of more than one system, these buttons are used for that purpose and are
therefore not available externally.
Connecting the Automation port to the MIP (manual intervention panel) port on a Pro-Bel
automation controller provides the operator with direct access to key automation controls,
permitting the ‘on air’ schedule to be effected without the need to access an automation edit
terminal.