Troubleshooting Steps
BURN/ELECTRICAL SHOCK HAZARD! Platen is HOT and can cause severe burns or severe shock.
Keep hands and objects out of the toaster unit! Failure to exercise caution may result in serious injury!
Turn the unit off, unplug it and let it cool down completely before touching or working on internal apparatus.
MASTER DISPLAY MESSAGES
PROBLEM
PROBABLE CAUSE
SOLUTION
Unit will not heat up.
Door ajar.
Ensure front and back doors are fully closed.
No power to unit.
Ensure power cord is connected to proper
receptacle.
Inoperable power cord.
Replace power cord.
Loose connection on power switch.
Tighten power switch connections.
Inoperable power switch.
Replace power switch.
High limit switch tripped.
Reset high level switch.
Inoperable temperature probe.
Replace temperature probe.
Inoperable platen.
Replace platen.
Unit heats up, but the conveyor does
not run.
Loose motor switch connection.
Tighten motor switch connection.
Inoperable motor.
Replace motor.
Inoperable motor switch.
Replace motor switch.
Stripped drive gear.
Replace drive gear.
Loose chain sprockets.
Adjust and tighten sprockets
Unit under- and over-heats, but does
not respond to programming.
Check temperature settings.
Adjust temperature set point setting. See
Management Programming.
Inoperable temperature probe.
Replace temperature probe.
Buns under- or over-done.
Check platen adjustment. See Operation
Manual.
Move platen adjustment knobs to the correct
product part setting.
Check conveyor temperature. From
READY screen, press the INFORMATION
button to display the actual platen
temperature.
Adjust temperature set point setting. See
Management Programming.
Improper toast time.
Adjust toast time as needed.