Regeneration Mode
1.
Function(Mode) set-up
Set up part.
ⴜ
of the LCD indicator changed or designate to REGENERATION by pushing
ⵐ
SELECT
button in the front part of the machine.
2. Standard(official) battery voltage set-up
Make the arrow(
ⶺ
)
located in the Battery Voltage / CV of part.
ⴘ
by pushing
ⵑ
ENTER. Designate the regenerated standard(official) battery voltage to the 12.0
by using
ⵒ
UP button and
ⵓ
DOWN button. After Set-up is completed by pushing
ⵑ
ENTER button again you can go on to the next work. (In this mode, you can
designate Battery Voltage of part.
ⴘ
to 6V, 8V or 12V)
3. Input battery capacity
Designate the showed exterior battery capacity to 100.0 by using
ⵒ
UP button and
ⵓ
DOWN button when
the arrow(
ⶺ
) located in the Capacity (Ah) / Current (A) of part.
ⴙ
.
4.
Internal resistance / CCA values measure
You can measure Internal Resistance(IR) and CCA value during the battery is connected
regardless of the arrow(
ⶺ
) location. Before regeneration work those values are displayed
right part of LCD indicator after pushing
ⵑ
ENTER button more than 2 seconds.
The displayed value in upper line is IR one and the lower line is CCA one.
This function cannot be worked during regeneration work after finishing regeneration
work the IR and CCA values in that moment displayed automatically.
5. Start of pause of regeneration
You can start regeneration work by pushing
ⵔ
START / STOP button after input Capacity (Ah) /
Current (A) in part.
ⴙ
and check IR and CCA values of before regeneration.
You can pause regeneration work by using
ⵔ
START / STOP button during the work.
6.
Progress condition display
After started regeneration supplied voltage is displayed in
ⴘ
Battery Voltage / CV under the
WORK part in real time and the hourly supplied current is displayed in
ⴙ
Capacity (Ah) / Current (A).
The SET part of
ⴚ
Run time(H:M) is automatically set-up time and the elapsed set-up work time is
displayed under the WORK part.
Ex) 12V / 100Ah Battery Regeneration Work
Control Button
SELECT Button
LCD Indicator
SET
The way of set value input in Regeneration Mode
or
SET
SET
or
2 seconds push
IR Value
CCA Value
DC 12V Battery Only
(Measure range : DC 11.0V ~ 14.0V)