Battery Tips

Industrial Lead Storage Battery is divided into cheap low-priced MF battery and high priced VRLA battery.

(VRLA : Valve Regulated Lead Acid battery ; sealed type maintenance free battery) 

- Industrial lead storage battery(=industrial battery) is using 12V standard(official) voltage battery (series connection among 6 cells 

  of 2V batteries inside) or using bank(bundle) type series connection among many high storage 2V cells.

- This battery is divided into two types one is GEL type which has jelly like electrolyte inside the other is AGM type which has AGM 

  (Absorptive Glass Mat) membranes.

- Industrial battery used in the place where need lots of discharge because it has thick lead plate. However it is inappropriate where 

  using lots of electricity in a short time because of narrow lead plate surface. It can cause current instability because the lead plate 

  melting to sulfuric acid solution time is later than current demand quantity.

- Though it has a little capacity but it can be used for a long time, high-priced battery is used for UPS(emergency electric) or standby 

  power and low-priced one is used for electric handcart or camping car.

- Industrial lead-acid battery can be judged in order of RC(reserve Capacity) value, Internal Resistance and Voltage.

This battery is mostly used in electric forklift, golf cart and so on which is moving by battery power and most of them are

high-priced maintenance battery.

- It used most of its charged energy in that day and then charge again, that is it used by Deep Cycle. Because its thick and wide lead plate, it 

  can deep discharge so it can do discharge 80% or more of its storage and charge it more than hundreds of time and called deep cycle battery.

- Because of its thick and wide lead plate and available for deep discharge it has long life span and it is used in variously.

- Deep cycle battery is used 6V standard(official) voltage battery (series connection among 3 cells of 2V), 8V battery 

  (series connection among 4 cells of 2V) or bank(bundle) type series connection among high storage many 2V cells.

- Deep cycle battery is used in electric forklift, golf cart, tower wagon and so on which using lots of electricity.

- In these days industrial UPS battery is using Deep cycle method to supplement low-priced industrial lead storage battery’s weakness.

- Deep cycle battery can be judged in order of RC(Reserve Capacity) value, Transparency of electrolyte, Gravity and Voltage.

The way of maintaining maintenance battery

- After regenerate/charge of battery, you should check the electrolyte and supply more distilled water if it is not enough. (Do not put sulfuric acid)

- Supplement of distilled water always has to be done after regeneration/charge. If you supply distilled water to discharged battery inner electrolyte

  can be overflown.

- If the battery temperature is over than 46.1

 you should stop the work and do the work again after cooling the heat.

- You should avoid flame or metal from the battery socket, do not smoke near the battery when regeneration/charge of it.

- When you discharge the battery you should do to the final discharge voltage. If the battery voltage is fallen under the final discharge voltage it can 

  have a problem.

- If you store it in winter or long period, you should do it after charge.

(Inner lead plate is thick but the surface is not wide.)

(Inner plate is thick and the lead plate is also thick)

(Internal lead plate is thin and wide)

Usually Car-start battery (= Car Battery) called MF battery (Maintenance Free battery) means maintenance free.

- Car Battery is normally used 12V standard(official) voltage battery. (series connection among 6 cells of 2V batteries inside).

- Lead-acid battery for normal car is SLI battery normally used for Start, Lighting and Ignition.

- Car battery is made for quick discharge and quick charge because most cars using heavy electricity when their start and charge is 

   done right after start.

- SLI battery is consist of structure for using heavy electricity in a short time so it is made by wider surface of the lead plate sunken 

   in sulfuric acid solution for that. However the lead plate is so thin in this feature so it can be harmed easily by external shock when it 

   discharged or charged for a long time.

- Car battery can be judged in order of RC(Reserve Capacity) value, CCA(Cold Cracking Ampere) and Voltage.

SLI (Car-Start) Battery

Industrial Lead storage Battery

Deep Cycle Battery

Summary of Contents for BASIC RPT-T300

Page 1: ...ual well not to get lost Please don t reprint or copy the image and the words because Repowertek Inc in Korea reserve all the copyrights of the contents to be used in this manual The exterior design a...

Page 2: ...ying intelligent smart control system with high frequency Pulse Technology to get the best possible charging of used batteries expecially car batteries This product is only for 6V 8V and 12V batteries...

Page 3: ...let It can cause an electric shock a fire Connect the cord of the power plug down Don t pull the electric cord electric wire when you unplug the power Otherwise in case of connecting it when the wire...

Page 4: ...can be caused Please take notice Please surely get rid of the metallic necklace and chain a bracelet other accessories on the body in case of the operation of regeneration and charge When the short c...

Page 5: ...n ow of the product should be prohibited thoroughly Input the same value as the specification of a battery at the moment of the set up Please check the specification of the battery on the exterior of...

Page 6: ...using the optimized high frequency pulse Optimized Automatic Regeneration Charge Algorithm It can be used in all types of lead acid battery by adjusting specialized automatic regeneration charge algo...

Page 7: ...atically START STOP Button When you push START STOP button the machine starts its work after inputting set value of battery voltage current and time is finished If you push START STOP button in workin...

Page 8: ...yed automatically in After part These are regenerated or charged battery conditions After Message Work progress indication and warning message are displayed Refer to the below items Run Time H M Regen...

Page 9: ...layed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worked during regener...

Page 10: ...values are displayed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worke...

Page 11: ...ause You can start the work by pushing START STOP button in front part of the machine after input 1 4 topic is completed and check the Internal Resistance and CCA measure of before regeneration You ca...

Page 12: ...7 RC Reserve Capacity value display The elapsed discharge time is displayed in Run Time H M in WORK part after started discharge The elapsed discharge time means RC Reserve Capacity value that is the...

Page 13: ...planation Ex 12V 100Ah Battery RegenerationWork Control Button SELECT Button LCD Indicator SET SET or Battery Condition Test Input way of Condition Test Identification set value This is a Damage Ident...

Page 14: ...C Voltage CCA Internal resistance CASE 2 CASE 1 CASE 3 CASE 4 PRIME charging voltage is going to 13V within about 40 minutes KEEP to Regenerate OK Test Finish PRIME charging voltage is not going to 13...

Page 15: ...lectric forklift golf cart tower wagon and so on which using lots of electricity In these days industrial UPS battery is using Deep cycle method to supplement low priced industrial lead storage batter...