background image

Correct Method of Use

 Operate the product following reading the manual surely.

      The proper charging of a battery can be initiated only  after carefully reading the manual. 

      When the equipment is operated without reading the manual outside the advised standard of operation, we take no responsibility for any consequent

     problems like a breakdown of the product and/or the damage of a battery.

Look around the surroundings again before installing a product and operating an equipment.

      This equipment uses the high voltage and high current. Please be advised to look around the surroundings again and check the danger of a current leakage 

      and an electric shock and and fire. Also look around the surroundings not to get the closed work space.

Don't use the product at the closed and humid place. Please use at the airy place.

      At the moment of the regeneration and charge of a battery, the sulfate attached on the lead of a battery is mixed with distilled water and is restored, and 

      the hydrogen gas(sulfurous acid gas) happens. The health may be harmful in case of being exposed to this gas at the closed space for a long time. 

      Don't be used at the closed working area, please be advised to be ventilated.

Please use the power outlet which is ground-functioned.

      Please surely use the power outlet which is ground-functioned. As the product is the equipment which uses the high voltage and high current, the danger of

      a current leakage and an electric shock may be caused. Please use it following installing the earthing device in case of using the outlet which is not ground-

      functioned. Also Don't use other electric products with ground wires.

Connect carefully and properly the terminal of a battery.

      Please connect the connector tongs of the product with the terminal of a battery exactly and tightly. If the connection is loosen up and is not connected 

      correctly, the operation of regeneration  and charge will not be implemented  properly. the current leakage and the electric shock may be caused.

The interval between the product and the battery to be restored should be kept more than 1M at least.

      If the battery begins being regenerated and charged, the hydrogen gas(sulfuric acid) happens  in the electrolyte of the internal battery. Only if the  interval 

      between the product and the battery is close, the component of sulfuric acid occurred in the battery can corrode the circuit board being owed into the

      internal product.  To protect this state, the interval between the product and the battery should be kept more than 1M.

      The air vents of the product is installed reversely against the battery, so the gas in ow of the product should be prohibited thoroughly.

Input the same value as the specification of a battery at the moment of the set-up.

      Please check the specification of the battery on the exterior of a battery before carrying out the discrimination and regeneration, charge of a battery. 

      The proper operation can be implemented only if the same setting value as the specification on the exterior of a battery. 

      The damage and overcharge & undercharge of a battery may be caused in case of the wrong setting value.

Make sure to wear protective gear for safety, and prepare washing utensils in advance.

      During working, make sure you should prepare an eye cleaning kit, water and soap close to you, in case your skin, clothes or eyes get in contact with acid 

      or electrolyte. During touching battery, make sure to wear globe and glasses.  Do not touch your eyes with your hands while working on batteries. 

      If your skin or clothes get in contact with electrolyte, make sure to clean immediately with clean water and soap. If electrolyte gets into your eyes, 

      immediately rinse them with clean water for about 10 minutes and contact your closest hospital.

Please check the impurity concentration of the electrolyte before restoring and charging the repair-typed battery.

      Please surely check the impurity concentration of the electrolyte following extracting the electrolyte of the internal Cell separately. If the concentration of the

      electrolyte is not transparent, is almost gray or black, and if the lump of the black impurity is floating in the electrolyte, it means that the interior lead plate of 

      the Cell is corroding and has already corroded. the regeneration and charge of a battery can not be carried out.

Replenish the flood type battery with only distilled water after regenerating and charging.

      Only if the regeneration is completed, and the value of a specific gravity is not clear, or only if the distilled water is replenished too much, and the value of a 

      specific gravity is not clear with the electrolyte overflowing, the sulfuric acid is replenished in the internal Cell, and never replenish the sulfuric acid other than it. 

      Please be advised to have help from an expert at the moment of replenishing the sulfuric acid.

Surely open the Cell Cap(supplementary lid for distilled water) and check whether the electrolyte is or is not 

     there before carrying out the regeneration or charge of the repair-typed battery. 

      Generally if all of the electrolyte of the internal Cell is evaporated, the regeneration and charge of the Cell is no longer possible. Only if the dried battery 

      with all of the distilled water being evaporated is regenerated or charged, the explosion may be caused.   So surely open the Cap the Battery Cell before 

      operating the product and check whether the electrolyte is in or is not there.

Summary of Contents for BASIC RPT-T300

Page 1: ...ual well not to get lost Please don t reprint or copy the image and the words because Repowertek Inc in Korea reserve all the copyrights of the contents to be used in this manual The exterior design a...

Page 2: ...ying intelligent smart control system with high frequency Pulse Technology to get the best possible charging of used batteries expecially car batteries This product is only for 6V 8V and 12V batteries...

Page 3: ...let It can cause an electric shock a fire Connect the cord of the power plug down Don t pull the electric cord electric wire when you unplug the power Otherwise in case of connecting it when the wire...

Page 4: ...can be caused Please take notice Please surely get rid of the metallic necklace and chain a bracelet other accessories on the body in case of the operation of regeneration and charge When the short c...

Page 5: ...n ow of the product should be prohibited thoroughly Input the same value as the specification of a battery at the moment of the set up Please check the specification of the battery on the exterior of...

Page 6: ...using the optimized high frequency pulse Optimized Automatic Regeneration Charge Algorithm It can be used in all types of lead acid battery by adjusting specialized automatic regeneration charge algo...

Page 7: ...atically START STOP Button When you push START STOP button the machine starts its work after inputting set value of battery voltage current and time is finished If you push START STOP button in workin...

Page 8: ...yed automatically in After part These are regenerated or charged battery conditions After Message Work progress indication and warning message are displayed Refer to the below items Run Time H M Regen...

Page 9: ...layed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worked during regener...

Page 10: ...values are displayed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worke...

Page 11: ...ause You can start the work by pushing START STOP button in front part of the machine after input 1 4 topic is completed and check the Internal Resistance and CCA measure of before regeneration You ca...

Page 12: ...7 RC Reserve Capacity value display The elapsed discharge time is displayed in Run Time H M in WORK part after started discharge The elapsed discharge time means RC Reserve Capacity value that is the...

Page 13: ...planation Ex 12V 100Ah Battery RegenerationWork Control Button SELECT Button LCD Indicator SET SET or Battery Condition Test Input way of Condition Test Identification set value This is a Damage Ident...

Page 14: ...C Voltage CCA Internal resistance CASE 2 CASE 1 CASE 3 CASE 4 PRIME charging voltage is going to 13V within about 40 minutes KEEP to Regenerate OK Test Finish PRIME charging voltage is not going to 13...

Page 15: ...lectric forklift golf cart tower wagon and so on which using lots of electricity In these days industrial UPS battery is using Deep cycle method to supplement low priced industrial lead storage batter...

Page 16: ...board If the switch is not working that can be inner switch problem so contact to our customer service for A S 2 year warranty Open the external case and reconnect grey Flat Cable connected to display...

Page 17: ...epair of others without Repowertek Inc technicians When performance and func onal trouble occurred in reten on period under the normal using Clean adjust using explana on and setup except machine trou...

Page 18: ...NF SFQPXFSUFL DPN is REPOWERTEK INC Regenerator Discharger Brand All products of REPOWERTEK INC in manufacture and production directly from South Korea BEF JO PSFB 2F Tosung Plaza 55 10 Gilju ro 77beo...