background image

Notices for Safety

In case of not keeping the below notices, 
                                                   the user can be killed and seriously injured.

Warning

Don't install in humid, oily, dusty places and  direct-lighted, rainwater-reaching places and closed spaces.

 It can cause an electric shock, and / or a fire.

Please use a grounded outlet for safety. Don't put to earth in a gas pipe, a plastic water pipe, a telephone wire only.

 Otherwise, it can cause an electric shock, a fire, a trouble, an explosion, so please surely use the grounded outlet.

Please use the electric power source of an alternating current AC80~120V or 210~250V / 50~60Hz and solely the product of  
the rated over 15A outlet, and don't extend the original electric cord.

 In case of the extended electric cord along with the multi-tap or other equipments being used, it can cause an electric shock, and / or a fire.

 Only if any transformer or inverter is used, it can cause an electric shock, a re. When switch on the AC power of transformer or inverter, 

     don’t plug RPT-T300.  Only after checking that you have a stable AC power source, then please plug RPT-T300.

 Different voltage / frequency / rated current condition can cause an electric shock or a fire.

Please regularly wipe off well the power source plug terminal and the extraneous bodies(dust, water etc) at the contacting part with a 
dried cloth

 Unplug the power and wipe off with a dried cloth. If the power plug gets wet, it can cause an electric shock, a fire.

Don't bend the electric cord(electric wire) by force. Don't pull it. Don't twist it. Don't tie it up. Also, Don't hang it on the metal part. 
Don't put it on the heavy object. Don't insert it among the objects.  Don't push it into the back of the product.

 It can cause an electric shock, a fire.

Surely connect the power plug to the end of the outlet, don't use the damaged power plug, the electric cord, the unstuck outlet. 

 It can cause an electric shock, a fire.

Connect the cord of the power plug down. Don't pull the electric cord(electric wire) when you unplug the power.

 Otherwise, in case of connecting it, when the wire inside the cord is cut off, it causes an electric shock, a fire.

 Hold and unplug the power plug because it can cause an electric shock, a fire.

Certainly exchange them not to be in danger before using the equipments when the power plug, the electric cord, the connecting cable 
are damaged.

Don't touch and operate the equipment with wet hands.

 It can cause an electric shock and the breakdown of a product.

Immediately interrupt the electric power source and connect the service center only if a strange sound, a burning smell, a smoke occur.

 It can cause an electric shock, and / or fire

Connect the service center after unplugging the power only if any water or the extraneous bodies go into the electric parts inside the product.

 It can cause an electric shock, and / or fire.

Don't open the case of the product with the power on. And don't disassemble, repair, remodel them absolutely at random except for a 
serviceman.

 Because of a high voltage flowing inside the product, in case of being exposed to the wave energy, there is some risk of an electric shock and a fire.

 Please connect a service center and be advised to be helped from it, only if the repair of the product is needed.

Smoking and the operation of welding and grinding should be strictly prohibited near the battery, when the regeneration and the charge 
are being operated.

 Due to the occurrence of the hydrogen gas(sulfurous acid gas) in the battery, take care of the risk of an explosion when smoking and sparking operations are 

     being performed near around.

Put on glasses or goggles to protect the eyes and wear working clothes suitable for an operation, when the regeneration and the charge 
are being operated

 Immediately wash with water in case that an electrolyte splash in the eyes, take notice of the sulfuric acid ingredients in the electrolyte which hurt the 

     garments.

Summary of Contents for BASIC RPT-T300

Page 1: ...ual well not to get lost Please don t reprint or copy the image and the words because Repowertek Inc in Korea reserve all the copyrights of the contents to be used in this manual The exterior design a...

Page 2: ...ying intelligent smart control system with high frequency Pulse Technology to get the best possible charging of used batteries expecially car batteries This product is only for 6V 8V and 12V batteries...

Page 3: ...let It can cause an electric shock a fire Connect the cord of the power plug down Don t pull the electric cord electric wire when you unplug the power Otherwise in case of connecting it when the wire...

Page 4: ...can be caused Please take notice Please surely get rid of the metallic necklace and chain a bracelet other accessories on the body in case of the operation of regeneration and charge When the short c...

Page 5: ...n ow of the product should be prohibited thoroughly Input the same value as the specification of a battery at the moment of the set up Please check the specification of the battery on the exterior of...

Page 6: ...using the optimized high frequency pulse Optimized Automatic Regeneration Charge Algorithm It can be used in all types of lead acid battery by adjusting specialized automatic regeneration charge algo...

Page 7: ...atically START STOP Button When you push START STOP button the machine starts its work after inputting set value of battery voltage current and time is finished If you push START STOP button in workin...

Page 8: ...yed automatically in After part These are regenerated or charged battery conditions After Message Work progress indication and warning message are displayed Refer to the below items Run Time H M Regen...

Page 9: ...layed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worked during regener...

Page 10: ...values are displayed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worke...

Page 11: ...ause You can start the work by pushing START STOP button in front part of the machine after input 1 4 topic is completed and check the Internal Resistance and CCA measure of before regeneration You ca...

Page 12: ...7 RC Reserve Capacity value display The elapsed discharge time is displayed in Run Time H M in WORK part after started discharge The elapsed discharge time means RC Reserve Capacity value that is the...

Page 13: ...planation Ex 12V 100Ah Battery RegenerationWork Control Button SELECT Button LCD Indicator SET SET or Battery Condition Test Input way of Condition Test Identification set value This is a Damage Ident...

Page 14: ...C Voltage CCA Internal resistance CASE 2 CASE 1 CASE 3 CASE 4 PRIME charging voltage is going to 13V within about 40 minutes KEEP to Regenerate OK Test Finish PRIME charging voltage is not going to 13...

Page 15: ...lectric forklift golf cart tower wagon and so on which using lots of electricity In these days industrial UPS battery is using Deep cycle method to supplement low priced industrial lead storage batter...

Page 16: ...board If the switch is not working that can be inner switch problem so contact to our customer service for A S 2 year warranty Open the external case and reconnect grey Flat Cable connected to display...

Page 17: ...epair of others without Repowertek Inc technicians When performance and func onal trouble occurred in reten on period under the normal using Clean adjust using explana on and setup except machine trou...

Page 18: ...NF SFQPXFSUFL DPN is REPOWERTEK INC Regenerator Discharger Brand All products of REPOWERTEK INC in manufacture and production directly from South Korea BEF JO PSFB 2F Tosung Plaza 55 10 Gilju ro 77beo...