background image

Product Specifications and Features

7 in 1 (7 Functions are included in 1 product.)

    

 It can do regeneration, charge or discharge work easily because 5 functions for battery regeneration are all included in RPT-T300.

      

 

REGENERATION MODE

 (Regeneration function) : It can extend the battery capacity.

      

 

CHARGE MODE

 (Charge function) : It can charge the battery.

      

 

POWER SUPPLY MODE

 (Expert function) : It can supply electricity by  freely choosing voltage, current and time like a power supply.

      

 

DISCHARGE MODE

 (Discharge function) : It can know RC value(discharge value) by discharge of the battery.

      

 

Battery Condition Test 

(Identification function) : It can understand if a battery can still be of use. 

(DC 12V Only)

 

IR Measuring

 (Internal Resistance measuring function) : It can compare Before condition or After condition internal resistance 

                                                                                                     in regeneration, charge or discharge work.

      

 

CCA Measuring

 (Cold Cranking Ampere) : It can compare Before condition or After condition CCA in regeneration, charge or 

                                                                               discharge work.

PRIME Smart Control System

     - It can regenerate and charge to 300Ah battery by controlling a minute 0.1 unit current or voltage, and do exact discharge.
     - It can be minimizing damage of electrodes and plates or maximizing sulphation sticking restraint by using the optimized 
       high frequency pulse.

Optimized Automatic Regeneration / Charge Algorithm

     It can be used in all types of lead-acid battery by adjusting specialized automatic regeneration / charge algorithm.  And it also can  
     extend and maintain battery life more than twice by preventing electrical or physical damage of battery in their regeneration / charge.

Wide Compatibility

     It can charge / regenerate various lead-acid battery from Car Start MF battery, industrial VRLA battery, to DC 6V, 8V Golf Cart battery.  
     Also, it can charge/ regenerate AGM type Battery which has jelly like electrolyte and AGM type battery which has a Absorptive Glass Mat 
     inner layer.

Safety

     It can do more safety work with overvoltage preventing function, input current deviation controlling function and Surge protecting function.

Product Specifications

Product Features

* If you need more information, please visit our website http://www.regenerator.co.kr

Product Name

Model No.

Size / Weight

Power consumption

Input Power

Battery Voltage

Battery Capacity

Regeneration Method

Max. Discharge Current

Discharge Capacity

BASIC Battery Charger & Discharger

RPT-T300

W 345mm X D 370mm X H 170mm 

(Without Cable)

 / 10.5 kg

Stand-by Approx. 20W ~ Max. Approx. 200W

AC 80 ~ 120V or 210 ~ 250V / 50~60Hz 

Standard  DC 6V, 8V, 12V Battery

All kinds Lead-Acid Battery 40Ah ~ 300Ah

Max. Output

150W (Max. 

10A

 / hour

)

Charge Current Inclusive High Frequency Pulse (Exclusive)

Max. 30A

Approx. 420 Watts

Summary of Contents for BASIC RPT-T300

Page 1: ...ual well not to get lost Please don t reprint or copy the image and the words because Repowertek Inc in Korea reserve all the copyrights of the contents to be used in this manual The exterior design a...

Page 2: ...ying intelligent smart control system with high frequency Pulse Technology to get the best possible charging of used batteries expecially car batteries This product is only for 6V 8V and 12V batteries...

Page 3: ...let It can cause an electric shock a fire Connect the cord of the power plug down Don t pull the electric cord electric wire when you unplug the power Otherwise in case of connecting it when the wire...

Page 4: ...can be caused Please take notice Please surely get rid of the metallic necklace and chain a bracelet other accessories on the body in case of the operation of regeneration and charge When the short c...

Page 5: ...n ow of the product should be prohibited thoroughly Input the same value as the specification of a battery at the moment of the set up Please check the specification of the battery on the exterior of...

Page 6: ...using the optimized high frequency pulse Optimized Automatic Regeneration Charge Algorithm It can be used in all types of lead acid battery by adjusting specialized automatic regeneration charge algo...

Page 7: ...atically START STOP Button When you push START STOP button the machine starts its work after inputting set value of battery voltage current and time is finished If you push START STOP button in workin...

Page 8: ...yed automatically in After part These are regenerated or charged battery conditions After Message Work progress indication and warning message are displayed Refer to the below items Run Time H M Regen...

Page 9: ...layed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worked during regener...

Page 10: ...values are displayed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worke...

Page 11: ...ause You can start the work by pushing START STOP button in front part of the machine after input 1 4 topic is completed and check the Internal Resistance and CCA measure of before regeneration You ca...

Page 12: ...7 RC Reserve Capacity value display The elapsed discharge time is displayed in Run Time H M in WORK part after started discharge The elapsed discharge time means RC Reserve Capacity value that is the...

Page 13: ...planation Ex 12V 100Ah Battery RegenerationWork Control Button SELECT Button LCD Indicator SET SET or Battery Condition Test Input way of Condition Test Identification set value This is a Damage Ident...

Page 14: ...C Voltage CCA Internal resistance CASE 2 CASE 1 CASE 3 CASE 4 PRIME charging voltage is going to 13V within about 40 minutes KEEP to Regenerate OK Test Finish PRIME charging voltage is not going to 13...

Page 15: ...lectric forklift golf cart tower wagon and so on which using lots of electricity In these days industrial UPS battery is using Deep cycle method to supplement low priced industrial lead storage batter...

Page 16: ...board If the switch is not working that can be inner switch problem so contact to our customer service for A S 2 year warranty Open the external case and reconnect grey Flat Cable connected to display...

Page 17: ...epair of others without Repowertek Inc technicians When performance and func onal trouble occurred in reten on period under the normal using Clean adjust using explana on and setup except machine trou...

Page 18: ...NF SFQPXFSUFL DPN is REPOWERTEK INC Regenerator Discharger Brand All products of REPOWERTEK INC in manufacture and production directly from South Korea BEF JO PSFB 2F Tosung Plaza 55 10 Gilju ro 77beo...

Reviews: