Part Name

 

LCD Display Indication Information

   

You can input battery specification and see progress work condition in real time.

 

POWER LED

   

When you switch on the rear switch 

 LCD display is turned on and the green light is turned on in 

POWER LED.

 

SELECT Button

   

It is a function selecting button if you push this button 

 item LED is turned on and you can select the function. 

                                  If you push this button again you can change the function.

 

Function Indicating LED

   

If you push 

 item button, each function’s LED are turned on and then you can check which function 

                                                      is selected.

 

ENTER Button

   

You can use this button to go on next work after inputting regeneration(or charge) battery type into the machine.

 

UP Button

    

You can use this button to increase set value in voltage, current or time set-up of the battery.  It increases 1 unit in 

                              REGENERATION MODE or CHARGE MODE and it increases 0.1 unit in POWER SUPPLY MODE or DISCHARGE MODE.  
                              If you push this button continuously the set value increased automatically.

 

DOWN Button

    

You can use this button to decrease set value in voltage, current or time set-up of the battery. It decreases 1 unit in

                                     REGENERATION MODE or CHARGE MODE and it decreases 0.1 unit in POWER SUPPLY MODE or DISCHARGE MODE. 
                                     If you push this button continuously the set value decreased automatically.

 

START / STOP Button

    

When you push START / STOP button the machine starts its work after inputting set value of battery voltage, 

                                                  current and time is finished. If you push START / STOP button in working the machine work is stopped.

 Battery Voltage / CV

   

When you input standard(official) battery voltage in SET part, the real time voltage of connected battery is

                                                displayed in WORK part.  You can set-up a Cut-off Voltage (CV) at DISCHARGRE Mode.

 Capacity / Current

   

When you input battery capacity in SET part, the supplied current amounts in real time are displayed in WORK part.

 Run Time (H:M)

   

The progress time of by a selected mode is automatically displayed in SET part, and elapsed working time is displayed

                                      in WORK part.

 

SET

   

Vertical line items under the SET, the battery set values(voltage, capacity, current and time) are displayed.

 WORK

   

If you push START button vertical line items under WORK are displayed in real time after inputting set values of vertical line items 

                     under the SET.

 IR, CCA

   

If you push the ENTER button more than 2 seconds (Or, if you push the START button), the internal resistance and CCA values

                       of connected battery are automatically displayed in Before part. If regeneration, charge and discharge work is finished, 
                       the internal resistance and CCA value are displayed in After part automatically.

When you turn on the switch, each LED flicking one time
and then above LCD indicator is changed into Setting Mode 
on the screen same as the right one.    

Displayed Contents of LCD Indicator

Summary of Contents for BASIC RPT-T300

Page 1: ...ual well not to get lost Please don t reprint or copy the image and the words because Repowertek Inc in Korea reserve all the copyrights of the contents to be used in this manual The exterior design a...

Page 2: ...ying intelligent smart control system with high frequency Pulse Technology to get the best possible charging of used batteries expecially car batteries This product is only for 6V 8V and 12V batteries...

Page 3: ...let It can cause an electric shock a fire Connect the cord of the power plug down Don t pull the electric cord electric wire when you unplug the power Otherwise in case of connecting it when the wire...

Page 4: ...can be caused Please take notice Please surely get rid of the metallic necklace and chain a bracelet other accessories on the body in case of the operation of regeneration and charge When the short c...

Page 5: ...n ow of the product should be prohibited thoroughly Input the same value as the specification of a battery at the moment of the set up Please check the specification of the battery on the exterior of...

Page 6: ...using the optimized high frequency pulse Optimized Automatic Regeneration Charge Algorithm It can be used in all types of lead acid battery by adjusting specialized automatic regeneration charge algo...

Page 7: ...atically START STOP Button When you push START STOP button the machine starts its work after inputting set value of battery voltage current and time is finished If you push START STOP button in workin...

Page 8: ...yed automatically in After part These are regenerated or charged battery conditions After Message Work progress indication and warning message are displayed Refer to the below items Run Time H M Regen...

Page 9: ...layed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worked during regener...

Page 10: ...values are displayed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worke...

Page 11: ...ause You can start the work by pushing START STOP button in front part of the machine after input 1 4 topic is completed and check the Internal Resistance and CCA measure of before regeneration You ca...

Page 12: ...7 RC Reserve Capacity value display The elapsed discharge time is displayed in Run Time H M in WORK part after started discharge The elapsed discharge time means RC Reserve Capacity value that is the...

Page 13: ...planation Ex 12V 100Ah Battery RegenerationWork Control Button SELECT Button LCD Indicator SET SET or Battery Condition Test Input way of Condition Test Identification set value This is a Damage Ident...

Page 14: ...C Voltage CCA Internal resistance CASE 2 CASE 1 CASE 3 CASE 4 PRIME charging voltage is going to 13V within about 40 minutes KEEP to Regenerate OK Test Finish PRIME charging voltage is not going to 13...

Page 15: ...lectric forklift golf cart tower wagon and so on which using lots of electricity In these days industrial UPS battery is using Deep cycle method to supplement low priced industrial lead storage batter...

Page 16: ...board If the switch is not working that can be inner switch problem so contact to our customer service for A S 2 year warranty Open the external case and reconnect grey Flat Cable connected to display...

Page 17: ...epair of others without Repowertek Inc technicians When performance and func onal trouble occurred in reten on period under the normal using Clean adjust using explana on and setup except machine trou...

Page 18: ...NF SFQPXFSUFL DPN is REPOWERTEK INC Regenerator Discharger Brand All products of REPOWERTEK INC in manufacture and production directly from South Korea BEF JO PSFB 2F Tosung Plaza 55 10 Gilju ro 77beo...

Reviews: