background image

Discharge Mode

2. Cut-off discharge voltage set-up 

   

Make the arrow(

)

 located in the Battery Voltage / CV of part. 

 by pushing 

 ENTER button. 

                                                                        Designate the discharge cut off voltage (CV) for 12V battery to 10.5 (normal 12V battery is 
                                                                        set-up 6 cells and normally designate the final discharge voltage to 1.75V per 1 cell) by using 

                                                              

 UP button and 

 DOWN button. You can go on to the next work by pushing 

 ENTER  

                                                                        button again after set-up (1.75V X 6 cells = 10.5V).

3. Set-up discharge current 

  

You can go on to the next work by pushing 

 ENTER button after designate the discharge current to 

                                                        25A (International standard discharge current for car start battery) by using 

 UP button and 

 DOWN

                                                        button when the arrow(

)

 is located in the Capacity (Ah) / Current (A) of part.    

                                                        (Warning : Basically the discharge current for all car start batteries are ‘25A’ according to the international 
                                                        standard. But in case of industrial batteries, the discharges current are differently adjusted according to the 
                                                        battery capacity, specification and time of the discharged battery.)

7.

 RC(Reserve Capacity) value display

   

The elapsed discharge time is displayed in 

 Run Time (H:M) in WORK part, after started 

                                                                            discharge. The elapsed discharge time means RC(Reserve Capacity) value that is the most
                                                                            important standard (Capacity Checking) of the battery.

The way of input Discharge Mode set values 

Control Button

SELECT Button

LCD Indicator

1.

 Function(Mode) set-up 

   

Set up part. 

 of the LCD indicator changed or designate to DISCHARGE by pushing 

 SELECT 

                                                     button in the front part of the machine.

SET

Ex) 12V / 100Ah Battery Discharge Work

SET

SET

4. Internal Resistance / CCA value measure 

 

  

Refer to “4. Internal Resistance / CCA value measure” in “Regeneration Mode” of

                                                                                        previous page.

5. Start and Pause 

 

  

You can start the discharge work by pushing 

 START / STOP button in the controller after input 1~3 values are 

                                        completed and check the Internal Resistance and CCA measure of before discharge.  You can pause the discharge
                                        work by using 

 START / STOP button during the discharge work.

6.

 Progress condition display

    

After started discharge work the current battery voltage is displayed in 

 Battery Voltage / CV under

                                                             the WORK the present discharging current amount in real time is displayed in 

 Capacity(Ah) 

                                                             / Current (A).

SET

   WORK

RC Value

or

or

Summary of Contents for BASIC RPT-T300

Page 1: ...ual well not to get lost Please don t reprint or copy the image and the words because Repowertek Inc in Korea reserve all the copyrights of the contents to be used in this manual The exterior design a...

Page 2: ...ying intelligent smart control system with high frequency Pulse Technology to get the best possible charging of used batteries expecially car batteries This product is only for 6V 8V and 12V batteries...

Page 3: ...let It can cause an electric shock a fire Connect the cord of the power plug down Don t pull the electric cord electric wire when you unplug the power Otherwise in case of connecting it when the wire...

Page 4: ...can be caused Please take notice Please surely get rid of the metallic necklace and chain a bracelet other accessories on the body in case of the operation of regeneration and charge When the short c...

Page 5: ...n ow of the product should be prohibited thoroughly Input the same value as the specification of a battery at the moment of the set up Please check the specification of the battery on the exterior of...

Page 6: ...using the optimized high frequency pulse Optimized Automatic Regeneration Charge Algorithm It can be used in all types of lead acid battery by adjusting specialized automatic regeneration charge algo...

Page 7: ...atically START STOP Button When you push START STOP button the machine starts its work after inputting set value of battery voltage current and time is finished If you push START STOP button in workin...

Page 8: ...yed automatically in After part These are regenerated or charged battery conditions After Message Work progress indication and warning message are displayed Refer to the below items Run Time H M Regen...

Page 9: ...layed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worked during regener...

Page 10: ...values are displayed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worke...

Page 11: ...ause You can start the work by pushing START STOP button in front part of the machine after input 1 4 topic is completed and check the Internal Resistance and CCA measure of before regeneration You ca...

Page 12: ...7 RC Reserve Capacity value display The elapsed discharge time is displayed in Run Time H M in WORK part after started discharge The elapsed discharge time means RC Reserve Capacity value that is the...

Page 13: ...planation Ex 12V 100Ah Battery RegenerationWork Control Button SELECT Button LCD Indicator SET SET or Battery Condition Test Input way of Condition Test Identification set value This is a Damage Ident...

Page 14: ...C Voltage CCA Internal resistance CASE 2 CASE 1 CASE 3 CASE 4 PRIME charging voltage is going to 13V within about 40 minutes KEEP to Regenerate OK Test Finish PRIME charging voltage is not going to 13...

Page 15: ...lectric forklift golf cart tower wagon and so on which using lots of electricity In these days industrial UPS battery is using Deep cycle method to supplement low priced industrial lead storage batter...

Page 16: ...board If the switch is not working that can be inner switch problem so contact to our customer service for A S 2 year warranty Open the external case and reconnect grey Flat Cable connected to display...

Page 17: ...epair of others without Repowertek Inc technicians When performance and func onal trouble occurred in reten on period under the normal using Clean adjust using explana on and setup except machine trou...

Page 18: ...NF SFQPXFSUFL DPN is REPOWERTEK INC Regenerator Discharger Brand All products of REPOWERTEK INC in manufacture and production directly from South Korea BEF JO PSFB 2F Tosung Plaza 55 10 Gilju ro 77beo...

Reviews: