Discharge Mode
2. Cut-off discharge voltage set-up
Make the arrow(
ⶺ
)
located in the Battery Voltage / CV of part.
ⴘ
by pushing
ⵑ
ENTER button.
Designate the discharge cut off voltage (CV) for 12V battery to 10.5 (normal 12V battery is
set-up 6 cells and normally designate the final discharge voltage to 1.75V per 1 cell) by using
ⵒ
UP button and
ⵓ
DOWN button. You can go on to the next work by pushing
ⵑ
ENTER
button again after set-up (1.75V X 6 cells = 10.5V).
3. Set-up discharge current
You can go on to the next work by pushing
ⵑ
ENTER button after designate the discharge current to
25A (International standard discharge current for car start battery) by using
ⵒ
UP button and
ⵓ
DOWN
button when the arrow(
ⶺ
)
is located in the Capacity (Ah) / Current (A) of part.
(Warning : Basically the discharge current for all car start batteries are ‘25A’ according to the international
standard. But in case of industrial batteries, the discharges current are differently adjusted according to the
battery capacity, specification and time of the discharged battery.)
7.
RC(Reserve Capacity) value display
The elapsed discharge time is displayed in
ⴚ
Run Time (H:M) in WORK part, after started
discharge. The elapsed discharge time means RC(Reserve Capacity) value that is the most
important standard (Capacity Checking) of the battery.
The way of input Discharge Mode set values
Control Button
SELECT Button
LCD Indicator
1.
Function(Mode) set-up
Set up part.
ⴜ
of the LCD indicator changed or designate to DISCHARGE by pushing
ⵐ
SELECT
button in the front part of the machine.
SET
Ex) 12V / 100Ah Battery Discharge Work
SET
SET
4. Internal Resistance / CCA value measure
Refer to “4. Internal Resistance / CCA value measure” in “Regeneration Mode” of
previous page.
5. Start and Pause
You can start the discharge work by pushing
ⵔ
START / STOP button in the controller after input 1~3 values are
completed and check the Internal Resistance and CCA measure of before discharge. You can pause the discharge
work by using
ⵔ
START / STOP button during the discharge work.
6.
Progress condition display
After started discharge work the current battery voltage is displayed in
ⴘ
Battery Voltage / CV under
the WORK the present discharging current amount in real time is displayed in
ⴙ
Capacity(Ah)
/ Current (A).
SET
WORK
RC Value
or
or