background image

Notices for Safety

Install at the strong bottom and the horizontal place.

 If the product is built on a slant, it can be slipped and destroyed. So it can cause a strange vibration, a noise and a breakdown.

Install at intervals with the walls and use at the few dusty place.

 Keep at regular intervals with the walls for the smooth function of protection against heat of the product. If the product is overheated, it can cause the 

     damaged product and a fire.

 Only if the product is used in the dusty place, the dust flowing into the equipment can cause the breakdown of the equipment.

When the product is built, install it in the place where the electric cord is unplugged easily.

 Because of the electric shock by the current leakage and the cause of a fire, install the electric outlet at the close place where the electric power source 

     can be dismantled in the moment of danger.

In case that the product is not used for a long time and a thunder or lightning strikes, unplug the electric power source.

 Please be advised to disconnect the electric power source unless the product is used because a stroke of lightning can cause the electric shock & a fire.

Don't put the objects(other instruments or tools) on the product.

 It can cause an electric shock, a fire, a breakdown and an injury.

When the operation is set, set it up exactly to be suited for the specification of a battery.

 Only if the specification of a battery and the set-up are different, the life-shortening and damage of a battery can be caused.

Don't put the metallic tool on the battery and never drop it down.

 If the metallic tool touches the terminal of a battery, the spark will happen and the battery will short-circuit, and the explosion can be caused. Please take notice.

Please surely get rid of the metallic necklace and chain, a bracelet, other accessories on the body in case of the operation of regeneration 
and charge.

 When the short-circuit of a battery happens, the electric shock and the injury can be caused with the big current flowing into the body.

The interval between the product and the battery should be kept more than 1m at least, specially install the air-intake direction of the 
equipment reversely against the battery.

 If the sulfurous acid gas of a battery flows into the inside of the product, the internal circuit board is corroded. So the product breakdown can be caused.

At the moment of the regeneration and charge of a battery, operate it at the place where there are flammable things and where is well 
ventilated.

 At the moment of the regeneration of a battery, as the sulfurous acid gas happens, the body can be injurious being exposed to it for a long time. 

     Please be advised to operate it at the place where is well ventilated. 

Please check the external state of the battery surely before the regeneration or charge of it.

 Please don't connect the +, - terminal of the damaged battery with the equipment at all, in case that the battery case is cracked and the corner of it is broken, 

     and only if the electrolyte of the internal battery is leaked.

1. Connect the red tongs with the anode and the black tongs with the cathode.

2. Only if the positive and negative is connected reversely and START is carried out, 
   "Check Connection" message is indicated on the LCD display with a warning sound, 
    then the equipment is not operated.

* If the any positive and negative terminal is not connected exactly and tightly, 
    the short-circuit can happen. Please take notice.

Red tongs

Black tongs

Connection of PRIME Regenerator and Battery

Only if the user does not keep, the user may be injured or
                                                                     the property may be damaged.

Caution

Summary of Contents for BASIC RPT-T300

Page 1: ...ual well not to get lost Please don t reprint or copy the image and the words because Repowertek Inc in Korea reserve all the copyrights of the contents to be used in this manual The exterior design a...

Page 2: ...ying intelligent smart control system with high frequency Pulse Technology to get the best possible charging of used batteries expecially car batteries This product is only for 6V 8V and 12V batteries...

Page 3: ...let It can cause an electric shock a fire Connect the cord of the power plug down Don t pull the electric cord electric wire when you unplug the power Otherwise in case of connecting it when the wire...

Page 4: ...can be caused Please take notice Please surely get rid of the metallic necklace and chain a bracelet other accessories on the body in case of the operation of regeneration and charge When the short c...

Page 5: ...n ow of the product should be prohibited thoroughly Input the same value as the specification of a battery at the moment of the set up Please check the specification of the battery on the exterior of...

Page 6: ...using the optimized high frequency pulse Optimized Automatic Regeneration Charge Algorithm It can be used in all types of lead acid battery by adjusting specialized automatic regeneration charge algo...

Page 7: ...atically START STOP Button When you push START STOP button the machine starts its work after inputting set value of battery voltage current and time is finished If you push START STOP button in workin...

Page 8: ...yed automatically in After part These are regenerated or charged battery conditions After Message Work progress indication and warning message are displayed Refer to the below items Run Time H M Regen...

Page 9: ...layed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worked during regener...

Page 10: ...values are displayed right part of LCD indicator after pushing ENTER button more than 2 seconds The displayed value in upper line is IR one and the lower line is CCA one This function cannot be worke...

Page 11: ...ause You can start the work by pushing START STOP button in front part of the machine after input 1 4 topic is completed and check the Internal Resistance and CCA measure of before regeneration You ca...

Page 12: ...7 RC Reserve Capacity value display The elapsed discharge time is displayed in Run Time H M in WORK part after started discharge The elapsed discharge time means RC Reserve Capacity value that is the...

Page 13: ...planation Ex 12V 100Ah Battery RegenerationWork Control Button SELECT Button LCD Indicator SET SET or Battery Condition Test Input way of Condition Test Identification set value This is a Damage Ident...

Page 14: ...C Voltage CCA Internal resistance CASE 2 CASE 1 CASE 3 CASE 4 PRIME charging voltage is going to 13V within about 40 minutes KEEP to Regenerate OK Test Finish PRIME charging voltage is not going to 13...

Page 15: ...lectric forklift golf cart tower wagon and so on which using lots of electricity In these days industrial UPS battery is using Deep cycle method to supplement low priced industrial lead storage batter...

Page 16: ...board If the switch is not working that can be inner switch problem so contact to our customer service for A S 2 year warranty Open the external case and reconnect grey Flat Cable connected to display...

Page 17: ...epair of others without Repowertek Inc technicians When performance and func onal trouble occurred in reten on period under the normal using Clean adjust using explana on and setup except machine trou...

Page 18: ...NF SFQPXFSUFL DPN is REPOWERTEK INC Regenerator Discharger Brand All products of REPOWERTEK INC in manufacture and production directly from South Korea BEF JO PSFB 2F Tosung Plaza 55 10 Gilju ro 77beo...

Reviews: