PowerBoss, Inc.
Copyright 2008
Armadillo
®
SW/10XV
PB # 4100034 / Rev. 01A08
Page 60
Operation, Maintenance and Troubleshooting
PROBLEM
CAUSE
SOLUTION
Hydraulic system noisy.
Air in system.
Check fluid level in
reservoir; check for loose
connections or leaks.
Relief valve dirty or damaged.
Clean or replace.
Loose suction line.
Tighten fittings.
Clogged section filter or pump Replace filter, clear line;
inlet line.
change fluid in reservoir if
dirty and flush system.
Internal pump or motor
Inspect and repair.
damage.
TROUBLESHOOTING (CONTINUED)