The block diagram shows an AURORA PVI-6000-OUTD with the two input DC-
DC converters; in the Wind version the 2 converters are always connected in
parallel.
Thanks to its high efficiency and excellent thermal design, the AURORA inverter
provides maximum power operation in a broad range of ambient temperatures.
The inverter is controlled by two independent DSPs (Digital Signal Processors)
and one central microprocessor.
This way, grid connection is controlled by two independent computers in full
compliance with electrical power supply and safety regulations.
The AURORA operating system continuously communicates with all functional
blocks and processes the data to ensure optimal performance, as well as the highest
possible efficiency under all wind speed and load conditions, always in full
compliance with the applicable directives, standards and regulations.
2.4
Safety Features
2.4.1
Anti-Islanding
When the local power distribution grid fails or when it is shut down for
maintenance, the AURORA inverter shall be disconnected from the grid, to protect
the people working on the grid, and in full compliance with the applicable national
standards and regulations. To avoid any possible islanding operation, the
AURORA inverter is equipped with the automatic disconnection protective system
called Anti-Islanding. The AURORA PVI-6000-OUTD-US-W model is equipped
with a state-of-the-art anti-islanding protection system certified to the following
standards and regulations:
¾
UL 1741 standard
2.4.2
Wind generator Ground Fault
A sophisticated ground protection circuit continually monitors the ground
connection. When a ground fault is detected, this circuit shuts down the AURORA
inverter and turns on the red LED on the front panel to indicate a ground fault
condition. The AURORA inverter is equipped with a terminal for the system
grounding conductor; see section 3.6 for more details.
NOTE:
For more details regarding the AURORA shutdown or possible
causes of malfunction, please, refer to sections 5.3 and 5.4.
2.4.3
Additional saftey features
The AURORA inverter is equipped with additional protections to guarantee safe
operation under any circumstances. The protections include:
Summary of Contents for AURORA PVI-6000-OUT-US-W
Page 1: ...AURORA Wind Inverters INSTALLATION AND OPERATION MANUAL Model number PVI 6000 OUT US W Rev 2 0...
Page 32: ...User Manual Page 32 of 77 PVI 6000 OUTD US W Rev 2 0 Fig 17 Data Transmission Options...
Page 60: ...User Manual Page 60 of 77 PVI 6000 OUTD US W Rev 2 0...
Page 73: ...User Manual Page 73 of 77 PVI 6000 OUTD US W Rev 2 0...
Page 74: ...User Manual Page 74 of 77 PVI 6000 OUTD US W Rev 2 0...
Page 75: ...User Manual Page 75 of 77 PVI 6000 OUTD US W Rev 2 0...
Page 76: ...User Manual Page 76 of 77 PVI 6000 OUTD US W Rev 2 0...
Page 77: ...User Manual Page 77 of 77 PVI 6000 OUTD US W Rev 2 0...