The following diagram shows how to connect multiple units in a daisy chain
configuration
.
Fig. 25 Daisy chain connection of multiple inverters
NOTE
:
When using a RS-485 link there can be up to 248 inverters
connected on the same link. Choose any address between 2 and 248
NOTE
:
When using a RS-485 link, in case one or more inverters are
added later to the system, always remember to switch back to the OFF
position the switch S2 of the former last inverter of the system.