Page 54 of 77
(PVI-6000-OUTD-US-W Rev.2.0)
5.5.6.6
Time
This function allows time and date setting.
5.5.6.7
Language
It is possible to set the national language or English.
5.5.6.8
START UP voltage
Start-up voltage can be set according to the characteristics of the wind
turbine/generator system. Voltage range can be 50V to 350V. The default setting is
50V. This parameter can be changed by means of the display keys.
5.5.6.9
Autotest
Self-test to verify correct operation of the protection and the grid interface device,
as required by UL 1741 standard.
Press ENTER to access all information of this section:
OV = Max. voltage
UV = Min. voltage
OF = Max. Frequency
UF = Min. Frequency
DC injection = DC component of the output current. This component shall not
exceed >0.5% of the inverter maximum rated current or the unit will switch off.
OV test
UV test
OF test
UF test
DC injection
Autotest
Time 14:21
Date 17 May 2006
VStart
50V
English
Italiano
Summary of Contents for AURORA PVI-6000-OUT-US-W
Page 1: ...AURORA Wind Inverters INSTALLATION AND OPERATION MANUAL Model number PVI 6000 OUT US W Rev 2 0...
Page 32: ...User Manual Page 32 of 77 PVI 6000 OUTD US W Rev 2 0 Fig 17 Data Transmission Options...
Page 60: ...User Manual Page 60 of 77 PVI 6000 OUTD US W Rev 2 0...
Page 73: ...User Manual Page 73 of 77 PVI 6000 OUTD US W Rev 2 0...
Page 74: ...User Manual Page 74 of 77 PVI 6000 OUTD US W Rev 2 0...
Page 75: ...User Manual Page 75 of 77 PVI 6000 OUTD US W Rev 2 0...
Page 76: ...User Manual Page 76 of 77 PVI 6000 OUTD US W Rev 2 0...
Page 77: ...User Manual Page 77 of 77 PVI 6000 OUTD US W Rev 2 0...