DATA MONITORING AND COMMUNICATION
6.1
Connection through RS-485 serial port or RJ12 connector
6.1.1
RS-485 serial port
The RS-485 serial port uses a three-wire cable: two wires are for signals and the
third one is for ground connection. Cable is routed through the holes located at the
bottom of the inverter. The holes are sealed with waterproof plugs (see Fig. 23).
Supplied cable glands must be installed in the suitable hole.
Fig.23. Holes for cables necessary for RS-485 port connection
or wiring for RJ12 connectors connection.
For easier installation, the inverter features two holes so that the input and output
cables can be separated in case more units are connected in a daisy chain.
1st PLUG
2nd PLUG