User Manual
Page 27 of 77
(PVI-6000-OUTD-US-W Rev.2.0)
Fig.12. DC section cables
Power-One recommends using the Wind Interface box p/n PVI-7200-Wind-
Interface-US. Refer to the Aurora Wind Interface User Manual for more details.
3.7
Step 6/6 (optional): Connection of the frequency signal from the wind
turbine.
If the MPPT is set using the wind turbine frequency, the frequency signals
available from the rectifier (marked Wind Speed + , Wind Speed – on the
AURORA Wind Interface) shall be connected to the pins WT and –WT
on the terminal bock of the AURORA inverter shown in Fig. 12.
3.8
How to access the internal terminal boards through the front panel
WARNING
: Shock hazard! Before removing the front panel, disconnect
AURORA from both the AC and DC side and allow 5 minutes for the
internal capacitors to discharge.
To remove the front panel, remove the 4 screws as shown in Fig. 13 using the flat-
blade screwdriver.
Wind
frequency
input