n
Always use the line cable delivered with the control unit.
n
Ensure, that the line cable is only connected to either
115 V AC
or
230 V AC
.
n
Ensure, that the power supply of the control unit is protected by an
external fuse type
2A MDL (at 230 V AC)
or
4A MDL (at 115 V AC)
.
Fig. 37: Power supply connector
Power supply properties
Property
Value Unit
Voltage
115 - 240 V AC
Tolerances
+10 / -15 %
Frequency
50 - 60 Hz
Maximum current (at 115 V)
4 A
Maximum current (at 230 V)
2 A
Maximum power consumption
180 W
Damage to the control unit!
Supply voltages not supported can cause damage to the control
unit.
(X1) Main Power Supply (1)
NOTICE
PA 8000 LW CNC control unit
Design and function