Property
Value Unit
Max. measurement input voltage
27 V
Measurement input current (at 24 V)
7 mA
Measurement input impedance
2200
Ω
Measurement operating voltage
OFF
5 V DC max.
Measurement operating voltage ON
11 V DC min.
Measurement input ON delay
200 ns
Measurement input OFF delay
300 ns
Measurement isolation
Opto coupler
Interface type
digital input 24 V
Each measurement input is referenced against its measurement
ground.
Probe wiring
When the RMS input is used in an application, each input of all used
axes must be wired in parallel.
3.3.1.3 Input schematic
Fig. 10: RMS input equivalent schematic
Probe Inputs
RMS Input Equivalent Schematic
PA 8000 LW CNC control unit
Design and function
25.09.2015 | 33
Summary of Contents for PA 8000 LW Series
Page 1: ...PA 8000 LW CNC control unit Installation instructions...
Page 12: ...PA 8000 LW CNC control unit General information 25 09 2015 12...
Page 85: ...4 4 Dimension sheet PA 8000 LW CNC control unit Technical data 25 09 2015 85...
Page 86: ...Fig 54 dimension sheet PA 8000 LW CNC control unit Technical data 25 09 2015 86...
Page 123: ...Fig 67 RMA Form RMA Form PA 8000 LW CNC control unit Service and return process 25 09 2015 123...
Page 126: ...PA 8000 LW CNC control unit Dismounting and decommissioning 25 09 2015 126...
Page 130: ...PA 8000 LW CNC control unit Proof of change 25 09 2015 130...