LED state
Module status
Off
No power supply (24 V)
OR
Hardware error
Slow flash
The module is not configured
Quick flash
The module is configured and the analog outputs are
set to 0 V
On
The module is configured and the analog outputs are
enabled
LED state
Module status
Off
Default
On
Access to this module
LED state
Module status
Off
Default
On
Bustest between control unit and the last PAMIO
module is active
LED state
Module status
Off
Error: The ambient temperature is above 60 °C
(140 °F). and all analog outputs are set to 0 V
Flashing
Warning: The ambient temperature is above 55 °C
(131 °F)
On
Default
LED state
Module status
Off
Axis is not connected
OR
Axis is connected and an encoder wire break has
been detected
Flashing
Axis is connected and a wrong sequence of signals on
track A and B has occurred
On
Axis is connected and no wire break has been
detected (default)
LED "Status" (1)
LED "Access" (2)
LED "Bustest" (3)
LED "Monitor" (4)
LED "Axis 1" (5)
PA 8000 LW CNC control unit
Troubleshooting
25.09.2015 | 112
Summary of Contents for PA 8000 LW Series
Page 1: ...PA 8000 LW CNC control unit Installation instructions...
Page 12: ...PA 8000 LW CNC control unit General information 25 09 2015 12...
Page 85: ...4 4 Dimension sheet PA 8000 LW CNC control unit Technical data 25 09 2015 85...
Page 86: ...Fig 54 dimension sheet PA 8000 LW CNC control unit Technical data 25 09 2015 86...
Page 123: ...Fig 67 RMA Form RMA Form PA 8000 LW CNC control unit Service and return process 25 09 2015 123...
Page 126: ...PA 8000 LW CNC control unit Dismounting and decommissioning 25 09 2015 126...
Page 130: ...PA 8000 LW CNC control unit Proof of change 25 09 2015 130...