- 61 -
0600_GB-Power-Control_8537
GB
POWEr COnTrOL - OPErATiOn
Driving lane switching
Press
“Special menu” key
• Menu base setting appears
- Select menu level using arrow keys
Driving lane rhythm
- Confirm with OK
Turning driving lane switching off
• Select “OFF” using arrow keys and confirm with OK
- Driving lane switching is deactivated
- The indicator in the main menu for driving lane cycle
and driving lane rhythm is now set at 0.
Symmetrical driving lanes
• Select “Symmetrical” using arrow keys and confirm
with OK.
- Select driving lane rhythm using +/- keys and confirm
with OK
- Possible driving lane rhythms:
2, , 4 ,5 ,6 ,7 ,8 ,9, 10 ,11, 12, 1, 14, 15
Asymmetrical driving lanes
• Select “Asymmetrical” using arrow keys and confirm
with OK
- Select driving lane rhythm using +/- keys and confirm
with OK
- Possible driving lane rhythms:
2
A
, 4
A
, 6
A
, 8
A
, 10
A
, 12
A
, 14
A
Special driving lanes
Special driving lanes are special types
A selected timing sequence here always qualifies a
special driving lane elements order on the seed drill.
• Select “Special driving lane” (Spezial-Fahrgasse“) using
arrow keys and confirm with OK
- Select driving lane rhythm using +/- keys and confirm
with OK
- Timing 4/18:
Drill machine working width: 4 meters
Trailing implement (fertilizer sprayer or spreader):
18 meters
- Timing sequence:
1L, 2, , 4, 5R, 6, 7, 8, 9, 10R, 11, 12, 1, 14L, 15,
16, 17, 18
L = left side switched
R = right side switched
Driving lanes meter
Relaying the driving lane cycle takes place automatically
through the “Running gear extended” sensor
- A time-invariant for relaying can be set
- This can be necessary to prevent an unwanted relay
when the machine is briefly raised.
Press
“Special menu” key
• Menu base setting appears
- Select menu level using arrow keys
Time-invariant
- Confirm with OK
- The value can be altered using the +/- keys, and be
saved by pressing long on the OK key.
See also section “driving lane cycle and driving lane
rhythm in Power Control operation main menu”