0800-GB VITASEM Multitronic
-
M
5 -
MULTiTrOniC ViTASEM
GB
5.1.4 Sowing shaft monitoring
Sowing shaft monitoring is enabled or disabled in this menu.
Firstly, the sowing shaft monitor symbol appears: <doSi> = Dosing, and secs. later
the monitoring state
Sowing shaft monitoring on = <
Ein
>
Sowing shaft monitoring off = <
AUS
>
Use arrow key
A
or
V
to enable or disable the monitoring function and press the
F
key to save. (See sect. 5.1.7)
The following step is hopper level monitoring adjustment.
5.1.5 Hopper level monitoring
This menu is used to enable or disable hopper level monitoring.
Firstly, the hopper level monitor symbol appears: <doSi> = Dosing, and secs. later
the monitoring state
Hopper level monitoring on = <
Ein
>
Hopper level monitoring off = <
AUS
>
Use arrow key
A
or
V
to enable or disable the monitoring function and press the
F
key to save. (See sect. 5.1.7)
The following step is delay time adjustment.
5.1.6 Delay time
Delay time t (t=time) involves delaying the switching impulses for automatic relaying of
the tramline cycles. The purpose of this function is to avoid incorrect activation.
Delay time is adjustable between 0.5 sec and 20.0 sec, steps of.
0 to 10 sec steps of 0,5 sec
10 to 20 sec steps of 1 sec
The following values should be entered before operating the unit.
Automatic relaying via::
Display readout
(= delay time in sec)
Shuttle valve pressure switch
1,5
Fendt signal plug socket
1,5
Ground wheel sensor
min
,5
Level compensator sensor
min
,5
Other values can also be entered however. Use arrow keys
A
or
V
to select delay time
and press the F key to save. (See sect.5.1.7)
The seed drill unit default adjustment setting procedure is now complete. The program
will now return to the main menu and the default setting symbol <AdJU> will be displayed
once more.
Press any of the four green display pushbuttons to exit this menu.
5.1.7 Saving the machine settings
If the pre-set default settings are altered, they must be saved to memory.
All settings can be saved in the same way:
Keep the
F
key pressed for 6 sec.
The display will start flashing after 2.5 sec and an acoustic signal will sound after 6
sec.
When the sound stops, the setting is saved.
The
F
key can now be released, giving automatic access to the following menu.
If the
F
key is released early, access is gained to the following menu, but any new setting
that may have been entered will be ignored and the previous setting retained.
6 Sek.