70
Illustration 8-23: 3-point calibration - Maximum
value
Illustration 8-24: 3-point calibration - Minimum
value
During calibration, a check is made to determine whether the measured voltage value in the
highest position of the 3-point is at least 0.1 V and whether the measured voltage value in the
lowest position of the 3-point is lower than in the highest position.
If the measured values are plausible, a confirmation screen opens. Once confirmed with "OK",
the new values are saved. If the values are not plausible, an error message is displayed.
8.2.8
Show hectare counter
If you select the softkey F12 "Show hectare counter" in the main view, you have the oppor-
tunity to display process data for an attached machine that is not operated via the ISOBUS.
The following information is presented (cf. Illustration 8-25):
•
Working width of attached machine,
•
hectare counter speed source,
•
working time,
•
distance travelled and
•
area worked.
A counter is kept for the working time, the distance travelled and the area worked. Each of
these three counters can be reset individually.
For the time, the distance and the area, a total value and a value in the working position are
given respectively. The total value shows the time, distance and area since the respective