General safety regulations
User
manual
EXPERT 75 - HW 1.0
4
If shielded cables are used, it must be ensured that the shield is connected to the attached
machine.
The maximum tightening torque of the fastening screws in the M5 threaded sockets on the
back of the device is 3 Nm. The thread reach must not exceed 7 mm.
The device supply line must be protected externally with a 1.8 A fuse. The tripping instant for
the fuse can be increased to a maximum of 3 A if required. The operating voltage limits
(+9 V - +30 V) and the temperature range (-20 °C - +70 °C) must be observed at all times.
"Warning"
When installing, make sure to comply with the applicable EMC
standard and the corresponding directive. The installation location, in-
tended use and device connection must be carried out accordingly.
"Caution"
The device should be placed at a sufficient distance from the op-
erator (esp. the head) according to the applicable safety rules.
"Attention"
The use of shielded cables is only permitted if the shield is con-
nected to the attached machine.
"Attention"
The maximum tightening torque of the fixing screws is 3 Nm.
The maximum thread reach is 7 mm.
"Attention"
The supply line must also be externally protected with a max-
imum 3 A fuse. The specification limits must not be exceeded/fallen short
of.
2.3
Life span
During the entire life of the device, care must always be taken by the operator not to damage
it or drop it. Moreover, the operator is responsible for ensuring the intactness of the housing