Log stop
3
4
5
2
1
1
Locking screw
4
Plate edge
2
Fixing plate with clamping lever
5
Scale
3
Log stop
The log length can be adjusted with the stop to a length of 15, 18, 20, 25, 27, 30, 33, 35,
40, 45, 50, 52 cm.
The log carriage must be fully out.
▪ Slide the locking screw to the top right.
▪ Tilt the clamping lever back and up, in order to lift the fixing plate.
▪ Move the log stop into the required position, allow the fixing plate to engage and clamp
in place again using the clamping lever.
You can read the wood length on the scale with the stop tube.
▪ Slide the locking screw to the bottom left.
The cut lengths of 25, 33 and 50 cm may only be selected when the log split length is a
max. of 100 cm. The narrow scrap pieces can otherwise result in the wood getting trapped
between the saw blade and the frame.
For log split lengths greater than 100 cm, use cut lengths of e.g. 27, 35 or 52 cm.
Electrical functions
Malfunctions
Fault
Cause
The electrical system is not working
When using an electric motor drive:
Main switch on the plug not switched on
Electric drive not switched on (green button)
Stop function active - deactivate
Safety switch on the protective cover faulty
- replace
When using a PTO drive:
Permanent current plug not connected -
connect
All:
Fuses in switchgear cabinet faulty - replace
Check electrical leads to contact or check for
cable break
5.1.2
5.1.3
Operation