Start-up
Check the machine for potential damage prior to every use.
▪ When doing so, pay particular attention to inspection activities in section "Checks [➙
Before starting to operate the machine, please check that the protective and safety systems
are working and also the hydraulic hoses and oil level.
Before each start-up, the condition of the electrical cables must be checked.
Check that the saw blade is firmly seated before each use.
If a fault occurs during operation, the machine must be shut down immediately and secured
so it cannot be switched on accidentally or started-up by unauthorised persons.
Electric motor drive
Three-phase mains connection
The machine must only be operated on electric circuits equipped with 30 mA FI fault current
protection or a Portable Residual Current Device (PRCD).
Work on electrical equipment must only be carried out by qualified electricians.
Type E11
Connect the machine to the mains:
▪ mains voltage 400 V (50 Hz)
▪ Circuit-breaker 32 A (tripping characteristic C)
▪ For the feed, a cable cross-section of at least 6 mm² must be used.
This is only the minimum cable cross-section; the cross-section for longer cable runs
must be determined by a qualified electrician.
▪ Switch on the master switch (on the plug).
1
2
1
Plug
2
Master switch
▪ First, turn the switch button of the switch to the Y position and wait for the motor to start
up. Then turn the switch to the delta position.
4
4.1
4.1.1
Start-up
18