ENGLISH
5
CORRECT USE OF DHMC THERMOSTAT
The control settings
The button switches on and off the DHMC heating,
moisturizing and drying functions.
The button for checking and modifi cation of the temperature.
In programming state the button is used to select the value to
be set or to check a control function.
In programming state the button is used to navigate inside
the program or to raise the selected value.
In programming state the button is used to navigate inside
the program or to lower the selected value.
The button for checking and modifi cation of the humidity. In
programming state the button is used to select the value to
be set or to check a control function.
The button for seeing the temperature of the product gauge.
The product gauge is an accessory and the button is used
only with a product gauge.
Main power switch. If all thermostats are in stand by state
(OFF), the main power switch switches on only the fan of the
heating cabinet.
Visual indicators
Light
State
Function
ON
Heating stage: The resistance of
the heating cassette is on and
heats the air.
ON
Cooling stage: Resistances are
off. The fan of the heating
cassette is on.
The fan of the heating cassette
is on.
ON
The drying function of the air is
on, the moisturizing cassette is
off.
ON
ON
The moisturizing function of the
air is on and the moisturizing
cassette heats the water.
USING THE WATER CASSETTE
Place the moisturising water
cassette after it has been fully
cleaned and dried and locate
the same into place
ensuring
that cassette is in contact with
the guiding plate.
Place the cover over the
moisturising Cassette.
Fill the basin of the cassette
with warm water. The cassette
will hold a maximum of two
litres.
Set the moisture control cover
according to the operational
requirements of the day.
The manufacturers
recommendations may be
seen on page 7. These being
for guidance only.
Turn on the power using the
main power switch located to
the left hand side of the DHMC
thermostat.
PLEASE NOTE!
The moisturising cassette must be correctly located
in place within the unit and be fi lled with water prior
to operation.
Check the water level within the moisturising
cassette at least every 4 hours adding water if so
required.
The termostat points out to check the amount of water
and to add water if so required. The screen shows “dry”
and the moisturising cassette is connected off.
Check the water and quit by pushing the button for
3 seconds when “rES” blinks three times on the screen.
The unit will then return to its normal state and the mois-
turising cassette is connected on.
The manufacturers setting of the DHMC unit is + 65°C
with the RH set at 50%.
Operational status
P1
Temperature gauge has been damaged.
P2
Product gauge has been damaged or it has come
off from the rapid connection.
P3
Humidity gauge is damaged.
Contact service.