
e.
Light the pilot.
f.
Remove the pilot flame adjustment cover.
g.
Turning the flame adjusting screw clockwise lowers the flame and the millivolt output.
Turning the screw counterclockwise increases flame size and millivolt output.
h. Rotate the screw in the direction to achieve a reading of 400 ±50 mv for thermopiles.
NOTE
Allow 3 to 5 minutes between flame adjustments to allow the reading to settle.
i. Replace the pilot flame adjusting screw cover.
1-11