3-31
VELIS Electro
Pilot's Operating Handbook
POH
-
128
-
00
-
40
-
001
PAGE REV. 0
PAGE
SECTION
3
EMERGENCY PROCEDURES
APPROVED
SOC bars are green when SOC % is between 100% and 30%, and turn amber
below 30%.
When SOC % is lower than 30%, expect the following caution message to
appear:
EPSI570C message
Annunciator
SOC<30%
(amber)
1
Reduce power
AS MUCH AS
POSSIBLE
2
Remaining SOC and RFT
MONITOR
3
Land
PREPARE TO LAND
NOTE
: A normal mission must terminate with SOC >= 30% at landing!
3.5.13
NO GO
-
AROUND AVAILABLE
If the flight continues and SOC% decreases to 15%, the following caution
message appears:
EPSI570C message
Annunciator
NO GO-AROUND AVAILABLE
(amber)
CAUTION:
The message above indicates that batteries are almost dis-
charged and the remaining energy is only su
ffi
cient for a few minutes of
flight. There is not enough energy left to perform a go-around safely.
1
Land
PREPARE TO LAND
WARNING:
If SOC < 15%, applying full power may cause battery voltage
to drop and eventual battery disconnection.
Summary of Contents for VELIS Electro
Page 9: ...SECTION 1...
Page 21: ...SECTION 2...
Page 36: ...This page is intentionally left blank...
Page 37: ...SECTION 3...
Page 40: ...This page is intentionally left blank...
Page 86: ...This page is intentionally left blank...
Page 108: ...This page is intentionally left blank...
Page 109: ...SECTION 4...
Page 126: ...This page is intentionally left blank...
Page 128: ...This page is intentionally left blank...
Page 140: ...This page is intentionally left blank...
Page 141: ...SECTION 5...
Page 167: ...SECTION 6...
Page 172: ...This page is intentionally left blank...
Page 173: ...SECTION 7...
Page 176: ...This page is intentionally left blank...
Page 209: ...SECTION 8...
Page 225: ...SECTION 9...
Page 227: ...APPENDIX 9 A1...