3-64
PAGE
POH
-
128
-
00
-
40
-
001
PAGE REV. 0
ENGINE COOLANT PUMP FAILURE
CAUTION:
ENGINE COOLANT PUMP FAILURE (amber)
Power lever
CUT OFF
Best glide speed
70 KIAS (flaps 0)
Engine temperatures
CHECK
Land (emergency)
PREPARE TO LAND
(use residual power for
obstacle avoidance only)
ELECTRICAL SYSTEM INSULATION
FAILURE
CAUTION:
SYSTEM ISOLATION FAILURE (amber)
Land
AS SOON AS PRACTICAL
CAUTION:
Any inspection/troubleshooting by the pilot shall be
avoided as it could lead to lethal electrical shock.
DC/DC CONVERTER FAILURES
CAUTION:
DC/DC COMMUNICATION FAILURE (amber)
or, if RPM >300:
DC/DC NOT WORKING (amber)
AUX BATTERY Voltage
MONITOR
Land
AS SOON AS PRACTICAL