3-57
POH
-
128
-
00
-
40
-
001
PAGE REV. 0
PAGE
BATTERY DISCONNECTED (single battery)
WARNING:
BATTERY F/R DISCONNECTED DUE TO:
OVERVOLTAGE
/
UNDERVOLTAGE
/
INTERLOCK
ERROR
/
INTERNAL
HARDWARE
FAILURE
(red)
A
ff
ected battery circuit
breaker
DISENGAGE
Other EPSI messages sub-
sequent to disconnection
ACKNOWLEDGE
SOC, RFT,
battery temperature
MONITOR
Reduce power
AS MUCH
AS POSSIBLE
Land
AS SOON AS
PRACTICAL
DOUBLE BATTERY DISCONNECTION
Emergency landing
procedure
PERFORM
OR