4-12
PAGE
VELIS Electro
Pilot's Operating Handbook
POH
-
128
-
00
-
40
-
001
PAGE REV. 0
SECTION
4
NORMAL PROCEDURES
Take o
ff
s into strong crosswinds are normally performed with the flaps set
at (+1). Start the take o
ff
run with the control column deflected into the wind.
Maintain direction with rudder, decreasing the aileron deflection as speed
increases. Rotate at a speed slightly higher than normal. When clear of the
ground, make a coordinated turn into the wind to correct for drift.
TAKE OFF
1
Power lever
FULL
2
Power indication
CHECK >= 50 kW
3
EPSI570C / annunciator
CHECK GREEN / NORMAL /
no warnings or cautions
4
Airspeed
CHECK increasing
5
Rotate
SET slight positive pitch
and lift o
ff
(50 KIAS)
6
Airspeed (initial climb)
57 - 60 KIAS
At safe altitude (300 ft AAL)
7
Flaps
0
8
Power lever
REDUCE TO MCP
9
Airspeed
INCREASE TO 75 KIAS (V
Y
)
CAUTION:
Add power gradually, as sudden bursts of power can cause air-
frame damage on certain runways due to stones and debris.
WARNING:
If, during the take o
ff
run, the motor PWR is less than 50 kW
with power lever in full position, abort the take o
ff
immediately, come to a
standstill and verify systems.
Summary of Contents for VELIS Electro
Page 9: ...SECTION 1...
Page 21: ...SECTION 2...
Page 36: ...This page is intentionally left blank...
Page 37: ...SECTION 3...
Page 40: ...This page is intentionally left blank...
Page 86: ...This page is intentionally left blank...
Page 108: ...This page is intentionally left blank...
Page 109: ...SECTION 4...
Page 126: ...This page is intentionally left blank...
Page 128: ...This page is intentionally left blank...
Page 140: ...This page is intentionally left blank...
Page 141: ...SECTION 5...
Page 167: ...SECTION 6...
Page 172: ...This page is intentionally left blank...
Page 173: ...SECTION 7...
Page 176: ...This page is intentionally left blank...
Page 209: ...SECTION 8...
Page 225: ...SECTION 9...
Page 227: ...APPENDIX 9 A1...