3-54
PAGE
POH
-
128
-
00
-
40
-
001
PAGE REV. 0
IN FLIGHT EMERGENCIES
COMPLETE POWER LOSS AFTER TAKE OFF
Best Glide or Landing
Speed (as appropriate)
ESTABLISH (70 - 60 KIAS)
BATT REAR/BATT FRONT
circuit breakers
DISENGAGE
PWR CTRL Circuit breaker
DISENGAGE
Flaps
AS REQUIRED
Land (emergency landing)
PREPARE TO LAND
COMPLETE IN-FLIGHT POWER LOSS
Best Glide speed (flaps 0)
70 KIAS
If time/altitude permits:
Motor restart in flight
procedure
ATTEMPT
If restart is not e
ff
ective:
Emergency landing
procedure
PERFORM