3-13
VELIS Electro
Pilot's Operating Handbook
POH
-
128
-
00
-
40
-
001
PAGE REV. 0
PAGE
SECTION
3
EMERGENCY PROCEDURES
APPROVED
While exiting the airplane, make sure the evacuation path is clear of other
aircraft, spinning propellers and/or other hazards.
3.4.5
BATTERY FAILURE AT SYSTEM START
-
UP
The system performs a self test on electrical components during the start-up
phase. Batteries are included in the checks.
In case of battery malfunction during system test (or temperatures below 0°C )
the following caution messages can appear:
EPSI570C message
Annunciator
BATTERY F/R SELFTEST
PBIT/LOW TEMP FAILED
(amber)
or
BATTERY F/R STARTUP FAILED
(amber)
or
CAUTION:
If these messages appear, do not continue start up. If reason is
low battery temperature, try to start up when battery temperature is >0°C. If
failure persists, or in case of other messages contact CAMO/CAO.
EPSI570C message
Annunciator
BATTERY VOLTAGES NOT
EQUAL
(amber)
1
DO NOT TAKE OFF
-
CAUTION:
If this message appears, do not take o
ff
. Try to fully recharge bat-
teries. If the message persists, contact CAMO/CAO.
Summary of Contents for VELIS Electro
Page 9: ...SECTION 1...
Page 21: ...SECTION 2...
Page 36: ...This page is intentionally left blank...
Page 37: ...SECTION 3...
Page 40: ...This page is intentionally left blank...
Page 86: ...This page is intentionally left blank...
Page 108: ...This page is intentionally left blank...
Page 109: ...SECTION 4...
Page 126: ...This page is intentionally left blank...
Page 128: ...This page is intentionally left blank...
Page 140: ...This page is intentionally left blank...
Page 141: ...SECTION 5...
Page 167: ...SECTION 6...
Page 172: ...This page is intentionally left blank...
Page 173: ...SECTION 7...
Page 176: ...This page is intentionally left blank...
Page 209: ...SECTION 8...
Page 225: ...SECTION 9...
Page 227: ...APPENDIX 9 A1...